The Adaptive Olfactory Measure of Threshold (ArOMa-T): A rapid test of olfactory function.

Weir Elisabeth M, Hannum Mackenzie E, Reed Danielle R, Joseph Paule V, Munger Steven D, Hayes John E, Gerkin Richard C

ПрепринтСтатьяПеревод в очереди

Аннотация

PURPOSE: Many widely-used psychophysical tests of olfaction have limitations that can create barriers to adoption outside research settings. For example, tests that measure the ability to identify odors may confound sensory performance with memory recall, verbal ability, and past experience with the odor. Conversely, threshold-based tests typically avoid these issues, but are labor intensive. Additionally, many commercially available olfactory tests are slow and may require a trained administrator, making them impractical for use in a short wellness visit or other broad clinical assessment.

METHODS

We tested the performance of the Adaptive Olfactory Measure of Threshold (ArOMa-T) -- a novel odor detection threshold test that employs an adaptive Bayesian algorithm paired with a disposable odor-delivery card -- in a non-clinical sample of individuals (n=534) at the 2021 Twins Day Festival in Twinsburg, OH.

RESULTS

Participants successfully completed the test in under 3 min with a false alarm rate of 9.6% and a test-retest reliability of 0.61. Odor detection thresholds differed by sex (~3.2-fold) and between the youngest and oldest age groups (~8.7-fold), consistent with prior work. In an exploratory analysis, we failed to observe evidence of detection threshold differences between participants who reported a history of COVID-19 and matched controls who did not. We also found evidence for broad-sense heritability of odor detection thresholds.

CONCLUSION

Together, these data indicate the ArOMa-T can determine odor detection thresholds. The ArOMa-T may be particularly valuable in clinical or field settings where rapid and portable assessment of olfactory function is needed.

Для цитирования: Weir Elisabeth M, Hannum Mackenzie E, Reed Danielle R, Joseph Paule V, Munger Steven D, Hayes John E, Gerkin Richard C. The Adaptive Olfactory Measure of Threshold (ArOMa-T): A rapid test of olfactory function.. medRxiv : the preprint server for health sciences. 2022. DOI: 10.1101/2022.03.08.22272086.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.