Li Lu-Ping, Vu Anthony T, Li Belinda S Y, Dunkle Eugene, Prasad Pottumarthi V
Аннотация
PURPOSE: To examine the benefit of using higher field strengths for BOLD MRI to detect changes in renal medullary oxygenation following pharmacological maneuvers.
MATERIALS AND METHODS: Renal BOLD MRI, primarily at 1.5 T, has been shown to be useful for monitoring changes in medullary oxygenation status. We performed the present studies on a 3.0 T scanner using a multiple gradient-echo (mGRE) sequence with a multicoil array to acquire 16 T2*-weighted images within a single breath-hold. Data were obtained before and after administration of furosemide (20 mg iv).
RESULTS: The baseline renal R2* (mean +/- SE) at 3.0 T was 37.4+/-1.2 Hz in the medulla, and 21.8 +/- 1.2 Hz in the cortex. The BOLD response to furosemide (DeltaR2*) at 3.0 T was 11.8 +/- 1.1 Hz in the medulla, and 3.0 +/- 0.5 Hz in the cortex.
CONCLUSION: Higher magnetic field strength is beneficial for renal BOLD MRI studies. The cortico-medullary contrast on the R2* map was significantly improved at 3.0 T, with no evidence of increased bulk susceptibility artifacts. Baseline R2* and DeltaR2* in the renal medulla at 3.0 T were both significantly higher compared to our previously reported data obtained at 1.5 T.
MATERIALS AND METHODS: Renal BOLD MRI, primarily at 1.5 T, has been shown to be useful for monitoring changes in medullary oxygenation status. We performed the present studies on a 3.0 T scanner using a multiple gradient-echo (mGRE) sequence with a multicoil array to acquire 16 T2*-weighted images within a single breath-hold. Data were obtained before and after administration of furosemide (20 mg iv).
RESULTS: The baseline renal R2* (mean +/- SE) at 3.0 T was 37.4+/-1.2 Hz in the medulla, and 21.8 +/- 1.2 Hz in the cortex. The BOLD response to furosemide (DeltaR2*) at 3.0 T was 11.8 +/- 1.1 Hz in the medulla, and 3.0 +/- 0.5 Hz in the cortex.
CONCLUSION: Higher magnetic field strength is beneficial for renal BOLD MRI studies. The cortico-medullary contrast on the R2* map was significantly improved at 3.0 T, with no evidence of increased bulk susceptibility artifacts. Baseline R2* and DeltaR2* in the renal medulla at 3.0 T were both significantly higher compared to our previously reported data obtained at 1.5 T.