m+Medelevator.RU
← Поиск публикаций
Critical care medicine · 2000

Dynamic study of the distribution of microcirculatory blood flow in multiple splanchnic organs in septic shock.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hiltebrand L B, Krejci V, Banic A, Erni D, Wheatley A M, Sigurdsson G H

Аннотация

OBJECTIVES: To study dynamic distribution of microcirculatory blood flow in multiple splanchnic organs during septic shock; to test the hypothesis that changes in microcirculatory blood flow in splanchnic organs correlate with changes in regional flow during septic shock.

DESIGN: A prospective, controlled, animal study.

SETTING: Animal laboratory in a university medical center.

SUBJECTS: Nine anesthetized and mechanically ventilated domestic pigs.

INTERVENTIONS: Systemic flow (cardiac output) was measured with thermodilution and regional (superior mesenteric artery) flow with transit time flowmetry. Local blood flow (microcirculatory flow) was continuously measured in splanchnic organs (gastric, jejunal, and colon mucosa, liver, and pancreas) and the kidney with multichannel laser Doppler flowmetry. Septic shock was induced with fecal peritonitis. After 240 mins of sepsis, intravenous fluids were administered to alter hypodynamic shock to hyperdynamic septic shock.

MEASUREMENTS AND MAIN RESULTS: In this severe septic shock model, systemic and regional flows decreased by approximately 50% during the first 240 mins. Similar reductions were recorded in microcirculatory flow in the mucosa of the stomach (-41%; p < .001) and colon (-47%; p < .001). In the jejunal mucosa, on the other hand, flow remained virtually unchanged. Microcirculatory flow was also significantly decreased in the liver (-49%; p < .001), pancreas (-56%; p < .001), and kidney (-44%; p < .001). Administration of intravenous fluids at 240 mins was followed by three-fold increases in systemic and regional flows (approximately 70% above baseline). In the jejunal mucosa, flow also increased significantly above baseline (42%; p < .001), whereas in the stomach and the colon, it barely reached baseline. Kidney blood flow increased to baseline, whereas pancreas and liver flows remained 26% (p < .05) and 34% (p < .001), respectively, below baseline.

CONCLUSION: Changes in microcirculatory blood flow in the splanchnic organs are heterogeneous, both in early hypodynamic and in hyperdynamic septic shock, and cannot be predicted from changes in systemic or regional flows. Microcirculatory blood flow in the jejunal mucosa remains constant during early septic shock, whereas pancreatic blood flow decreases significantly more than regional flow.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты