MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.contraception.2009.05.004

Медицинская библиотека · Contraception · 2009

Extended regimens of the vaginal contraceptive ring: cycle control.

Guazzelli Cristina Aparecida Falbo, Barreiros Fernando Augusto, Barbosa Ricardo, de Araújo Fábio Fernando, Moron Antonio Fernandes

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Oral contraceptives used for extended periods of time have been extensively studied because of their potential benefits; however, there have been few publications on extended regimen of vaginal rings. The aim of this study was to compare the bleeding patterns of women using extended regimens of the vaginal ring or oral contraceptives.

STUDY

DESIGN

Prospective cohort involving 150 women: 75 used vaginal rings that release 120 mcg of etonogestrel and 15 mcg of ethinyl estradiol daily, and 75 took oral contraceptives containing ethinyl estradiol 0.3 mcg and desogestrel 150 mcg. Both groups used their respective contraceptive method over continuous periods of 84 days, followed by a 7-day pause, during 1 year.

RESULTS

The total number of scheduled bleeding and spotting days decreased significantly during the 1-year period of the study for both methods (p=.001), and this decrease was significantly higher for oral contraceptive users. Similarly, during the study period, there was a significant reduction in the total number of unscheduled bleeding and spotting days for both methods (p=.01), but this decrease was significantly higher among vaginal ring users (p=.003).

CONCLUSION

Vaginal ring used on an extended regimen is a contraceptive method that offers good cycle control.

Для цитирования: Guazzelli Cristina Aparecida Falbo, Barreiros Fernando Augusto, Barbosa Ricardo, de Araújo Fábio Fernando, Moron Antonio Fernandes. Extended regimens of the vaginal contraceptive ring: cycle control.. Contraception. 2009. DOI: 10.1016/j.contraception.2009.05.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.