MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/ac3008847

Медицинская библиотека · Analytical chemistry · 2012

Charge heterogeneity of monoclonal antibodies by multiplexed imaged capillary isoelectric focusing immunoassay with chemiluminescence detection.

Michels David A, Tu Andrea W, McElroy Will, Voehringer David, Salas-Solano Oscar

СтатьяПеревод в очереди

Аннотация

Characterization of charge heterogeneity of recombinant monoclonal antibodies (mAbs) requires high throughput analytical methods to support clone selection and formulation screens. We applied the NanoPro technology to rapidly measure relative charge distribution of mAbs in early stage process development. The NanoPro is a multiplexed capillary-based isoelectric immunoassay with whole-column imaging detection. This assay offers specificity, speed and sensitivity advantages over conventional capillary isoelectric focusing (CIEF) platforms. After CIEF, charge variants are photochemically immobilized to the wall of a short coated capillary. Once immobilized, mAbs are probed using a secondary anti-IgG conjugated with horseradish peroxidase. After flushing away excess reagents, secondary antibodies bound to their targets are then detected by chemiluminescence upon incubation with peroxidase reactive substrates. Charge heterogeneity as determined by chemiluminescence was similar to that measured by conventional CIEF technology with absorbance detection for purified mAbs and contaminated mAbs derived directly from host cellular extract. Upon method optimization, the automated CIEF immunoassay was applied to several mAbs of varying isoelectric points, demonstrating the suitability of NanoPro as a rugged high-throughput product characterization tool. Furthermore, qualification of detection sensitivity, precision, and dynamic range are reported with discussion of its advantages as an alternative approach to rapidly characterize charge variants during process development of mAbs.

Для цитирования: Michels David A, Tu Andrea W, McElroy Will, Voehringer David, Salas-Solano Oscar. Charge heterogeneity of monoclonal antibodies by multiplexed imaged capillary isoelectric focusing immunoassay with chemiluminescence detection.. Analytical chemistry. 2012. DOI: 10.1021/ac3008847.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.