Evaluation of Fibrin Clot Interaction with Dental Implant after Different Surface Treatments: An In Vitro Study.

Jalaluddin Mohammad, Ramanna Pavithra K, Swain Monalisa, Sonkesriya Subhash, Rana Priyanka, Kumari Deesha, Derbala Dina A A, Mirza Linda F, Mushtaq Shazia, Beshir Saiid E M

СтатьяПеревод в очереди

Аннотация

AIM: The current study was carried out to assess the interaction between fibrin clots and dental implants following various surface treatments.

MATERIALS AND

METHODS

In this investigation, 45 dental implants with dimensions of 16 mm in length and 5 mm in diameter were utilized. They were divided up into three groups, each consisting of fifteen samples. Group I: Control; Group II: Ultraviolet (UV) light treated; and group III: Sandblasted and acid-etching (SLA) treated. Healthy volunteers' venous blood samples were drawn into vacutainer tubes without the use of anticoagulants. The samples were centrifuged for 3 minutes at 2700 rpm in a table centrifuge. The entire implant was submerged in room-temperature liquid fibrinogen for 60 minutes. Then, scanning electronic microscopy (SEM) was used to examine each sample. The inter- and intragroup assessments were obtained using the Mann-Whitney U test and the Kruskal-Wallis test; p-values less than 0.05 were regarded as statistically significant.

RESULTS

The maximum adhesion of fibrin clot was found in SLA treated group (2.42 ± 0.10) followed by the UV light-treated group (2.18 ± 0.08) and control group (1.20 ± 0.02). There was a statistically significant difference found between the three surface-treated groups (p < 0.001).

CONCLUSION

All surface-treatment methods exhibit adhesion between the implant surface and the fibrin clot. However, the highest adherence of fibrin clot was found in SLA treated group compared to the UV light-treated and control group.

CLINICAL SIGNIFICANCE: The physical and chemical characteristics of an implant's surface have a significant impact on the way blood clots organize. At the interface between the implant and the bone, blood clot production can initiate and facilitate the healing process. How to cite this article: Jalaluddin M, Ramanna PK, Swain M, et al. Evaluation of Fibrin Clot Interaction with Dental Implant after Different Surface Treatments: An In Vitro Study. J Contemp Dent Pract 2024;25(3):276-279.

Для цитирования: Jalaluddin Mohammad, Ramanna Pavithra K, Swain Monalisa, Sonkesriya Subhash, Rana Priyanka, Kumari Deesha, Derbala Dina A A, Mirza Linda F, Mushtaq Shazia, Beshir Saiid E M. Evaluation of Fibrin Clot Interaction with Dental Implant after Different Surface Treatments: An In Vitro Study.. The journal of contemporary dental practice. 2024. DOI: 10.5005/jp-journals-10024-3653.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.