MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Archives de pediatrie : organe officiel de la Societe francaise de pediatrie · 1994

[Doppler echocardiography in the evaluation of volume expansion effects in newborn infants].

Pladys P, Bétrémieux P, Lefrançois C, Schleich J M, Gourmelon N, Le Marec B

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The effects of volume expansion on the cardiac output (CO) of newborns have not been studied, so that the indications for colloid infusion are not well standardized.

POPULATION AND

METHODS

Twenty one newborns (14 preterm and seven term babies) were studied before the 7th day of life. Thirteen had patent ductus arteriosus (PDA) and six had ischemic cardiopathy. Hemodynamic data indicated that these babies should be given 20 ml/kg of a 10% albumin solution. Pulsed-wave Doppler echocardiography was performed before and after infusion.

RESULTS

Only 11 newborns had initial low Co (less than 260 ml/kg/min in patients with PDA; less than 200 ml/kg/min in the others). The increases in CO (31 +/- 25% vs 7 +/- 11%, P < 0.01) and of mean aortic flow velocity (MAFV) (34.6 +/- 19.5% vs 7.2 +/- 6.1%, P < 0.01) were significantly greater in this group. The increases in mean arterial pressure (+4 +/- 5 mmHg) and CO (+20 +/- 18%) were significant (P < 0.01) for all patients, both premature and term (with or without PDA and ischemic cardiopathy). The increase in CO was correlated with the initial CO and the cutaneous refilling time but was not correlated with the increase in arterial pressure. The sizes of the ventricles and left atrium grew significantly but that of the right atrium did not. Analysis of the increase in stroke volume in terms of the end diastolic diameter of the left ventricle indicated that the cardiac reserves varied according to the Starling relation.

CONCLUSION

Evaluation of MAFV and CO plus diagnosis of PDA are all needed in order to assess whether volume expansion is accurate or not, since, clinical data obtained during the neonatal period are insufficient to do this.

Для цитирования: Pladys P, Bétrémieux P, Lefrançois C, Schleich J M, Gourmelon N, Le Marec B. [Doppler echocardiography in the evaluation of volume expansion effects in newborn infants].. Archives de pediatrie : organe officiel de la Societe francaise de pediatrie. 1994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.