MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2008.12.003

Медицинская библиотека · Talanta · 2008

Speciation of mercury by ionic liquid-based single-drop microextraction combined with high-performance liquid chromatography-photodiode array detection.

Pena-Pereira Francisco, Lavilla Isela, Bendicho Carlos, Vidal Lorena, Canals Antonio

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Room temperature ionic liquids can be considered as environmentally benign solvents with unique physicochemical properties. Ionic liquids can be used as extractant phases in SDME, being compatible with chromatographic systems. A single-drop microextraction method was developed for separation and preconcentration of mercury species (MeHg(+), EtHg(+), PhHg(+) and Hg(2+)), which relies on the formation of the corresponding dithizonates and microextraction of these neutral chelates onto a microdrop of an ionic liquid. Afterwards, the separation and determination were carried out by high-performance liquid chromatography with a photodiode array detector. Variables affecting the formation and extraction of mercury dithizonates were optimized. The optimum conditions found were: microextraction time, 20 min; stirring rate, 900 rpm; pH, 11; ionic liquid type, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]); drop volume, 4 microL; and no sodium chloride addition. Limits of detection were between 1.0 and 22.8 microg L(-1) for the four species of mercury, while the repeatability of the method, expressed as relative standard deviation, was between 3.7 and 11.6% (n=8). The method was finally applied to the determination of mercury species in different water samples.

Для цитирования: Pena-Pereira Francisco, Lavilla Isela, Bendicho Carlos, Vidal Lorena, Canals Antonio. Speciation of mercury by ionic liquid-based single-drop microextraction combined with high-performance liquid chromatography-photodiode array detection.. Talanta. 2008. DOI: 10.1016/j.talanta.2008.12.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.