m+Medelevator.RU
← Поиск публикаций
Journal of pharmaceutical and biomedical analysis · 2020

Lack of concordance between EMIT assay and LC-MS/MS for Therapeutic Drug Monitoring of Mycophenolic Acid: Potential increased risk for graft rejection?

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

De Nicolò Amedeo, Ianniello Alice, Benagli Cinzia, Della Bruna Roberto, Keller Franco, Antonucci Miriam, D'Avolio Antonio, Cantù Marco

Аннотация

Therapeutic drug monitoring (TDM) of immunosuppressive drugs is crucial in organ-transplanted patients to prevent rejection or toxic effects due to inadequate dosage. Mycophenolic acid (MPA) is a commonly used immunosuppressant in this setting. Nowadays, MPA concentrations are monitored by Enzyme Multiplied Immunoassay Technology (EMIT), and Liquid Chromatography (LC)-based techniques, particularly coupled to Tandem Mass Spectrometry (LC-MS/MS). This study evaluates the concordance between TDM results for MPA obtained through CE-IVD EMIT and LC-MS/MS assays in plasma samples. LC-MS/MS quantification was based on a commercial kit and the analytical performance in terms of accuracy was tested through external proficiency tests and inter-laboratory comparison with a home-made HPLC-UV method. Both these evaluations confirmed the reliability of the LC-MS/MS method (1.6 % and 9.0 % of bias, respectively). Conversely, the comparison between EMIT and LC-MS/MS showed overestimation by EMIT of 33.5 %. This bias resulted concentration-dependent, ranging from 46.4 % in the concentration range of 1-2 mg/L, to 21.4 % over 4 mg/L. Considering the theoretical clinical impact of this overestimation, a fraction comprised between 12.4 % and 31.4 % of samples which resulted over three different minimum effective concentration values by EMIT (no indication for dose adjustment) had discordant indications by LC-MS/MS (dose adjustment needed). Concluding, this study highlights a clinically relevant systematic overestimation of MPA concentration by EMIT, supporting the switch to LC-MS/MS techniques for TDM purpose. However, further prospective studies are needed in order to evaluate the clinical impact of switching the TDM activity from EMIT to LC-MS/MS in a larger cohort in a long period.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты