MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-021-89223-2

Медицинская библиотека · Scientific reports · 2021

Influence of intraoperative vasopressor use on indocyanine green fluorescence angiography: first evaluation in an experimental model.

Al-Taher Mahdi, Pruimboom Tim, Schols Rutger M, Okamoto Nariaki, Bouvy Nicole D, Stassen Laurents P S, van der Hulst René R W J, Kugler Michael, Hostettler Alexandre, Noll Eric, Marescaux Jacques, Diemunsch Sophie, Diana Michele

СтатьяПеревод в очереди

Аннотация

Intraoperative indocyanine green (ICG) fluorescence angiography has gained popularity and acceptance in many surgical fields for the real-time assessment of tissue perfusion. Although vasopressors have the potential to preclude an accurate assessment of tissue perfusion, there is a lack of literature with regards to its effect on ICG fluorescence angiography. An experimental porcine model was used to expose the small bowel for quantitative tissue perfusion assessment. Three increasing doses of norepinephrine infusion (0.1, 0.5, and 1.0 µg/kg/min) were administered intravenously over a 25-min interval. Time-to-peak fluorescence intensity (TTP) was the primary outcome. Secondary outcomes included absolute fluorescence intensity and local capillary lactate (LCL) levels. Five large pigs (mean weight: 40.3 ± 4.24 kg) were included. There was no significant difference in mean TTP (in seconds) at baseline (4.23) as compared to the second (3.90), third (4.41), fourth (4.60), and fifth ICG assessment (5.99). As a result of ICG accumulation, the mean and the maximum absolute fluorescence intensity were significantly different as compared to the baseline assessment. There was no significant difference in LCL levels (in mmol/L) at baseline (0.74) as compared to the second (0.82), third (0.64), fourth (0.60), and fifth assessment (0.62). Increasing doses of norepinephrine infusion have no significant influence on bowel perfusion using ICG fluorescence angiography.

Для цитирования: Al-Taher Mahdi, Pruimboom Tim, Schols Rutger M, Okamoto Nariaki, Bouvy Nicole D, Stassen Laurents P S, van der Hulst René R W J, Kugler Michael, Hostettler Alexandre, Noll Eric, Marescaux Jacques, Diemunsch Sophie, Diana Michele. Influence of intraoperative vasopressor use on indocyanine green fluorescence angiography: first evaluation in an experimental model.. Scientific reports. 2021. DOI: 10.1038/s41598-021-89223-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.