Incongruous effect of phenylephrine on changes in cerebral blood volume measured by near-infrared spectroscopy (NIRS) indicating extracranial contamination.

Клиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Moerman Annelies T, Vandenheuvel Michaël, Tuybens Pieter-Jan, Van Gompel Carla, De Hert Stefan G

Аннотация

We assessed extracranial contamination of the near-infrared spectroscopy (NIRS) signal during administration of phenylephrine. The study was performed with NIRO 200NX which employs both the Modified Beer-Lambert (MBL) method to measure total hemoglobin (tHb, expressed in µM), and Spatially Resolved Spectroscopy (SRS) to measure total hemoglobin content (nTHI, expressed in arbitrary units (a.u.)). SRS tends to not be affected by extracranial blood flow. As vasoconstriction with phenylephrine mainly occurs in the extracranial area, we hypothesized that if NIRS measurements are indeed prone to extracranial contamination, tHb will be more affected by the administration of phenylephrine than nTHI. After ethical committee approval, 20 consenting cardiac surgery patients were included. Phenylephrine was administered whenever clinically indicated and its effect on nTHI and tHb was evaluated. To adjust for the difference in raw scale units, Z-scores were calculated. Data were analyzed with Wilcoxon Signed Ranks Test and the Hodges-Lehmann method. A total of 191 data sets were obtained in 20 patients (10 male, 65 ± 15 years, 77 ± 16 kg, 166 ± 11 cm). The median difference before and after administration of phenylephrine was - 0.006 a.u. [95%CI - 0.010 to - 0.002] (p < 0.001) and - 0.415 µM [95%CI - 0.665 to - 0.205] (p < 0.001) for nTHI and tHb, respectively. The median difference between the Z-scores of nTHI and tHb was - 0.02 [95%CI - 0.04 to - 0.003] (p = 0.03), with a higher variability in the Z-scores of tHb. Phenylephrine induced significant larger changes in MBL values compared to SRS values, indicating that the MBL method might be more prone to extracranial contamination. Trial and clinical registry: Trial registration number: B670201939459, ethical committee number: 2019/0265, date of approval: March 19, 2019.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты