Safety and effectiveness of midazolam for cirrhotic patients undergoing endoscopic variceal ligation.

Jo Hee Bum, Lee Jun Kyu, Jang Dong Kee, Kang Hyoun Woo, Kim Jae Hak, Lim Yun Jeong, Koh Moon-Soo, Lee Jin Ho

СтатьяПеревод в очереди

Аннотация

BACKGROUND/AIMS: Endoscopic variceal ligation (EVL) is an established treatment for esophageal variceal bleeding. Midazolam (MDZ) is most commonly used for sedation during endoscopic procedures. However, adverse events (AEs) may occur more frequently in patients with cirrhosis due to altered MDZ metabolism.

MATERIALS AND

METHODS

We retrospectively reviewed the records of 325 patients with cirrhosis who received EVL.

RESULTS

No significant differences were found in treatment outcome and procedure time among 151 patients in the MDZ group and 169 patients in the non-MDZ group. Desaturation (23.2% vs. 7.7%, p<0.01), bradycardia (22.5% vs. 17.2%, p=0.03), and hepatic encephalopathy (HE) (6.6% vs. 0.6%, p<0.01) were more common in the MDZ group than in the non-MDZ group. Logistic regression analyses revealed that an Eastern Cooperative Oncology Group (ECOG) score of ≥2 (p<0.01) and the use of MDZ (p<0.01) were associated with the development of overall AEs. An ECOG score of ≥2 (p=0.01), high serum creatinine level (p=0.02), and the use of MDZ (p<0.01) were significant risk factors for HE.

CONCLUSION

Extreme caution should be taken when sedating patients with cirrhosis receiving EVL due to the AEs associated with the use of MDZ.

Для цитирования: Jo Hee Bum, Lee Jun Kyu, Jang Dong Kee, Kang Hyoun Woo, Kim Jae Hak, Lim Yun Jeong, Koh Moon-Soo, Lee Jin Ho. Safety and effectiveness of midazolam for cirrhotic patients undergoing endoscopic variceal ligation.. The Turkish journal of gastroenterology : the official journal of Turkish Society of Gastroenterology. 2018. DOI: 10.5152/tjg.2018.17589.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.