BACKGROUND

Adrenomedullin (AM) is a potent vasodilator peptide. Plasma AM levels are increased in heart diseases and in sepsis. Heart surgery under cardiopulmonary bypass (CPB) induces a systemic inflammatory response.

METHODS

We measured plasma AM, cAMP (the second messenger of AM), C-reactive protein (CRP) and haemodynamic parameters in 29 patients undergoing elective open heart surgery, before, during and after anaesthesia and CPB as well as on the first morning after surgery.

RESULTS

Basal AM levels were higher than normal and correlated with systolic pulmonary pressure and pulmonary capillary pressure, but not with other haemodynamic parameters. AM increased during CPB and remained elevated 24 h after the start of surgery. Plasma cAMP increased only at the end of CPB. CRP was increased only in the last sample. At the end of CPB and at the end of surgery AM levels were higher in patients with basal ejection fraction<40% compared with those with ejection fraction >60% [456+/-386 vs 252+/-343 (P<0.03) and 832+/-781 vs 391+/-356 pg/ml (P<0.05), respectively].

CONCLUSION

We conclude that AM, as inflammation-related cytokines, increases during and after CPB, that cAMP response is unrelated to AM and that AM response is higher in those patients with worse basal ejection fraction.

Для цитирования: Amado J A, Fidalgo I, García-Unzueta M T, Montalbán C, Del Moral I, Pazos F, Diago C. Patients with poor preoperative ejection fraction have a higher plasma response of adrenomedullin in response to open heart surgery.. Acta anaesthesiologica Scandinavica. 1999. DOI: 10.1034/j.1399-6576.1999.430808.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.