MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2024.08.016

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2024

Circulating factors, in both donor and ex-situ heart perfusion, correlate with heart recovery in a pig model of DCD.

Graf Selianne, Egle Manuel, Sanz Maria-Nieves, Segiser Adrian, Clavier Alexia, Arnold Maria, Gsponer Didier, Bartkevics Maris, Kadner Alexander, Siepe Matthias, Vermathen Peter, Longnus Sarah

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Heart transplantation with donation after circulatory death and ex-situ heart perfusion offers excellent outcomes and increased transplantation rates. However, improved graft evaluation techniques are required to ensure effective utilization of grafts. Therefore, we investigated circulating factors, both in-situ and ex-situ, as potential biomarkers for cardiac graft quality.

METHODS

Circulatory death was simulated in anesthetized male pigs with warm ischemic durations of 0, 10, 20, or 30 minutes. Hearts were explanted and underwent ex-situ perfusion for 3 hours in an unloaded mode, followed by left ventricular loading for 1 hour, to evaluate cardiac recovery (outcomes). Multiple donor blood and ex-situ perfusate samples were used for biomarker evaluation with either standard biochemical techniques or nuclear magnetic resonance spectroscopy.

RESULTS

Circulating adrenaline, both in the donor and at 10 minutes ex-situ heart perfusion, negatively correlated with cardiac recovery (p < 0.05 for all). We identified several new potential biomarkers for cardiac graft quality that can be measured rapidly and simultaneously with nuclear magnetic resonance spectroscopy. At multiple timepoints during unloaded ex-situ heart perfusion, perfusate levels of acetone, betaine, creatine, creatinine, fumarate, hypoxanthine, lactate, pyruvate and succinate (p < 0.05 for all) significantly correlated with outcomes; the optimal timepoint being 60 minutes.

CONCLUSIONS

In heart donation after circulatory death, circulating adrenaline levels are valuable for cardiac graft evaluation. Nuclear magnetic resonance spectroscopy is of particular interest, as it measures multiple metabolites in a short timeframe. Improved biomarkers may allow more precision and therefore better support clinical decisions about transplantation suitability.

Для цитирования: Graf Selianne, Egle Manuel, Sanz Maria-Nieves, Segiser Adrian, Clavier Alexia, Arnold Maria, Gsponer Didier, Bartkevics Maris, Kadner Alexander, Siepe Matthias, Vermathen Peter, Longnus Sarah. Circulating factors, in both donor and ex-situ heart perfusion, correlate with heart recovery in a pig model of DCD.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2024. DOI: 10.1016/j.healun.2024.08.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.