Procedural Variables Influencing Stereotactic Accuracy and Efficiency in Deep Brain Stimulation Surgery.

Mirzadeh Zaman, Chen Tsinsue, Chapple Kristina M, Lambert Margaret, Karis John P, Dhall Rohit, Ponce Francisco A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Deep brain stimulation (DBS) is well-established, evidence-based therapy for Parkinson disease, essential tremor, and primary dystonia. Clinical outcome studies have recently shown that "asleep" DBS lead placement, performed using intraoperative imaging with stereotactic accuracy as the surgical endpoint, has motor outcomes comparable to traditional "awake" DBS using microelectrode recording (MER), but with shorter case times and improved speech fluency.

OBJECTIVE

To identify procedural variables in DBS surgery associated with improved surgical efficiency and stereotactic accuracy.

METHODS

Retrospective review of 323 cases with 546 leads placed (August 2011-October 2014). In 52% (n = 168) of cases, patients were asleep under general anesthesia without MER. Multivariate regression identified independent predictors of reduced surgery time and improved stereotactic accuracy.

RESULTS

MER was an independent contributor to increased procedure time (+44 min; P = .03). Stereotactic accuracy was better in asleep patients. Accuracy was improved with frame-based stereotaxy at head of bed 0° vs frameless stereotaxy at head of bed 30°. Improved accuracy was also associated with shorter procedures (r = 0.17; P = .049). Vector errors were evenly distributed around the planned target for the globus pallidus internus, but directionally skewed for the subthalamic (medial-posterior) and ventral intermediate nuclei (medial-anterior).

CONCLUSION

Distinct procedural variables in DBS surgery are associated with reduced case times and improved stereotactic accuracy.

Для цитирования: Mirzadeh Zaman, Chen Tsinsue, Chapple Kristina M, Lambert Margaret, Karis John P, Dhall Rohit, Ponce Francisco A. Procedural Variables Influencing Stereotactic Accuracy and Efficiency in Deep Brain Stimulation Surgery.. Operative neurosurgery (Hagerstown, Md.). 2019. DOI: 10.1093/ons/opy291.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.