MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf00417771

Медицинская библиотека · European journal of applied physiology and occupational physiology · 1987

A non-invasive method for measuring inspiratory muscle fatigue during progressive isocapnic hyperventilation in man.

Vilozni D, Bar-Yishay E, Beardsmore C S, Shochina M, Wolf E, Godfrey S

СтатьяПеревод в очереди

Аннотация

Eleven normal adults each performed a ten minute progressive isocapnic hyperventilation (PIHV) test in which ventilatory levels were increased every two minutes. All subjects exhibited mechanical fatigue by failing to maintain the target of 80% of maximum voluntary ventilation (MVV). The mean ventilation at this level was 67.5 +/- 1.4% MVV. This fatigue was accompanied by a fall in transdiaphragmatic pressure. During the test the EMG of the sternomastoid (SM) was monitored by surface electrodes and was analyzed using fast-fourier transform. The centroid frequency (Fc) fell as ventilation increased, and correlated negatively with the inability to achieve target ventilation(r = -0.99, p less than 0.015). Five subjects performed the test while the diaphragmatic EMG was recorded from an oesophageal electrode (DIes) and from surface electrodes (DIs). The Fc of DIes fell with increasing ventilation levels (r = -0.95, p less than 0.05) and there was a correlation between the Fc changes of both DIes and the SM (r = -0.92, p less than 0.001). The Fc of DIs did not correlate with either mechanical performance or the Fc of DIes, because of contamination of surface signals by signals from expiratory muscles. It is concluded that the PIHV along with surface monitoring of EMG activity from the sternomastoid can serve as a non-invasive method for evaluating inspiratory muscle fatigue.

Для цитирования: Vilozni D, Bar-Yishay E, Beardsmore C S, Shochina M, Wolf E, Godfrey S. A non-invasive method for measuring inspiratory muscle fatigue during progressive isocapnic hyperventilation in man.. European journal of applied physiology and occupational physiology. 1987. DOI: 10.1007/bf00417771.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.