MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsami.8b17772

Медицинская библиотека · ACS applied materials & interfaces · 2019

-Phosphorescent Mesoporous Surface Imprinting Microspheres: Preparation and Application for Transferrin Recognition from Biological Fluids.

Miao Yanming, Sun Xiaojie, Lv Jinzhi, Yan Guiqin

СтатьяПеревод в очереди

Аннотация

The relationship between the thickness of surface molecularly imprinted polymers (MIPs) and specific recognition performance of transferrin (Trf) as well as the quantitative relation between the grafting amount of Mn-ZnS room-temperature phosphorescence (RTP) quantum dots (QDs) (short for PQDs) and RTP signals for recognition of Trf was analyzed in this study. Based on analysis results, RTP protein mesoporous imprinting microspheres (SiO2-PQDs-MIPs) with high specificity and strong interference resistance were developed using a mesoporous SiO2 nanomaterial that can create more three-dimensional precise recognition sites as the matrix and using PQDs with strong resistance to background fluorescence interference as the luminescent materials. A discriminatory analysis of Trf was realized by the phosphorescence quenching principle based on light quenching caused by the photoinduced electron transfer. The concentration range, limit of detection, relative standard deviation, and imprinting factor of Trf detection under pH 7.4 are 0.05-1.0 μM, 0.014 μM, 3.23%, and 3.09, respectively. Although the sensing signals of SiO2-PQDs-MIPs for proteins are based on the phosphorescence of PQDs, they are particularly suitable for specific recognition and accurate quantitative detection of proteins in biological fluids. Research conclusions are expected to realize high-efficiency recognition of target proteins in actual biological samples.

Для цитирования: Miao Yanming, Sun Xiaojie, Lv Jinzhi, Yan Guiqin. -Phosphorescent Mesoporous Surface Imprinting Microspheres: Preparation and Application for Transferrin Recognition from Biological Fluids.. ACS applied materials & interfaces. 2019. DOI: 10.1021/acsami.8b17772.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.