DOI 10.1164/rccm.200601-107oc

Медицинская библиотека · American journal of respiratory and critical care medicine · 2006

Comparison of biomarkers in exhaled breath condensate and bronchoalveolar lavage.

Jackson Abigail S, Sandrini Alessandra, Campbell Charlotte, Chow Sharron, Thomas Paul S, Yates Deborah H

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

RATIONALE: Exhaled breath condensate (EBC) is increasingly studied as a noninvasive research method of sampling the lungs, measuring several biomarkers. The exact site of origin of substances measured in EBC is unknown, as is the clinical applicability of the technique. Special techniques might be needed to measure EBC biomarkers.

OBJECTIVES

To assess biomarker concentrations in clinical disease and investigate the site of origin of EBC, we compared EBC and bronchoalveolar lavage (BAL) biomarkers in 49 patients undergoing bronchoscopy for clinical indications.

MEASUREMENTS: We measured exhaled nitric oxide, 8-isoprostane, hydrogen peroxide, total nitrogen oxides, pH, total protein, and phospholipid (n = 33) and keratin (n = 15) to assess alveolar and mucinous compartments, respectively. EBC was collected over 10 min using a refrigerated condenser according to European Respiratory Society/American Thoracic Society recommendations, and BAL performed immediately thereafter.

RESULTS

8-Isoprostane, nitrogen oxides, and pH were significantly higher in EBC than in BAL (3.845 vs. 0.027 ng/ml, 28.4 vs. 3.8 microM, and 7.35 vs. 6.4, respectively; p < 0.001). Hydrogen peroxide showed no difference between EBC and BAL (17.5 vs. 20.6 microM, p = not significant), whereas protein was significantly higher in BAL (33.8 vs. 183.2 microg/ml, p < 0.001). Total phospholipid was also higher in EBC, but keratin showed no difference. No significant correlation was found between EBC and BAL for any of the biomarkers evaluated either before or after correction for dilution.

CONCLUSIONS

In clinical disease, markers of inflammation and oxidative stress are easily measurable in EBC using standard laboratory techniques and EBC is readily obtained. However, EBC and BAL markers do not correlate.

Для цитирования: Jackson Abigail S, Sandrini Alessandra, Campbell Charlotte, Chow Sharron, Thomas Paul S, Yates Deborah H. Comparison of biomarkers in exhaled breath condensate and bronchoalveolar lavage.. American journal of respiratory and critical care medicine. 2006. DOI: 10.1164/rccm.200601-107oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.