MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00003072-200307000-00003

Медицинская библиотека · Clinical nuclear medicine · 2003

Somatostatin receptor scintigraphy for bronchial carcinoid follow-up.

Fanti Stefano, Farsad Mohsen, Battista Giuseppe, Monetti Francesco, Montini Gian Carlo, Chiti Arturo, Savelli Giordano, Petrella Francesco, Bini Alessandro, Nanni Cristina, Romeo Annadina, Franchi Roberto, Bombardieri Emilio, Canini Romeo, Monetti Nino

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Somatostatin receptor scintigraphy (SRS) has been used to diagnose bronchial carcinoids (BC) and is a valuable tool for accurate staging of BC. The aim of this study was to evaluate the role of SRS in restaging BC and following patients after treatment.

METHODS

Thirty-one patients (18 male, 13 female) with confirmed BC who were referred during the last 7 years were included. Patients were examined via chest radiograph (12 studies), chest or abdominal computed tomography (CT; 28 scans), chest magnetic resonance imaging (2 scans), and liver ultrasound (5 scans).

RESULTS

Overall, in 22 patients (71%), SRS confirmed the data obtained by other diagnostic procedures (16 negative and 6 positive findings). In 6 patients, SRS showed focal lesions not previously demonstrated. In 2 patients, SRS resolved uncertain findings of CT. In 1 patient, SRS showed fewer lesions compared with CT. In 8 of 31 patients, important diagnostic information obtained by SRS was not revealed by any other imaging procedure.

CONCLUSION

Our results indicate that SRS is a reliable, noninvasive method that could be considered the principal follow-up procedure in patients with BC.

Для цитирования: Fanti Stefano, Farsad Mohsen, Battista Giuseppe, Monetti Francesco, Montini Gian Carlo, Chiti Arturo, Savelli Giordano, Petrella Francesco, Bini Alessandro, Nanni Cristina, Romeo Annadina, Franchi Roberto, Bombardieri Emilio, Canini Romeo, Monetti Nino. Somatostatin receptor scintigraphy for bronchial carcinoid follow-up.. Clinical nuclear medicine. 2003. DOI: 10.1097/00003072-200307000-00003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.