MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/jacs.8b04975

Медицинская библиотека · Journal of the American Chemical Society · 2018

No Structure-Switching Required: A Generalizable Exonuclease-Mediated Aptamer-Based Assay for Small-Molecule Detection.

Canoura Juan, Wang Zongwen, Yu Haixiang, Alkhamis Obtin, Fu Fengfu, Xiao Yi

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The binding of small molecules to double-stranded DNA can modulate its susceptibility to digestion by exonucleases. Here, we show that the digestion of aptamers by exonuclease III can likewise be inhibited upon binding of small-molecule targets and exploit this finding for the first time to achieve sensitive, label-free small-molecule detection. This approach does not require any sequence engineering and employs prefolded aptamers which have higher target-binding affinities than structure-switching aptamers widely used in current small-molecule detecting assays. We first use a dehydroisoandrosterone-3-sulfate-binding aptamer to show that target binding halts exonuclease III digestion four bases prior to the binding site. This leaves behind a double-stranded product that retains strong target affinity, whereas digestion of nontarget-bound aptamer produces a single-stranded product incapable of target binding. Exonuclease I efficiently eliminates these single-stranded products but is unable to digest the target-bound double-stranded product. The remaining products can be fluorescently quantified with SYBR Gold to determine target concentrations. We demonstrate that this dual-exonuclease-mediated approach can be broadly applied to other aptamers with differing secondary structures to achieve sensitive detection of various targets, even in biological matrices. Importantly, each aptamer digestion product has a unique sequence, enabling the creation of multiplex assays, and we successfully demonstrate simultaneous detection of cocaine and ATP in a single microliter volume sample in 25 min via sequence-specific molecular beacons. Due to the generality and simplicity of this assay, we believe that different DNA signal-reporting or amplification strategies can be adopted into our assay for target detection in diverse analytical contexts.

Для цитирования: Canoura Juan, Wang Zongwen, Yu Haixiang, Alkhamis Obtin, Fu Fengfu, Xiao Yi. No Structure-Switching Required: A Generalizable Exonuclease-Mediated Aptamer-Based Assay for Small-Molecule Detection.. Journal of the American Chemical Society. 2018. DOI: 10.1021/jacs.8b04975.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.