MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2017.08.002

Медицинская библиотека · JACC. Clinical electrophysiology · 2017

Cardiac Rhythm Disturbances in Hemodialysis Patients: Early Detection Using an Implantable Loop Recorder and Correlation With Biological and Dialysis Parameters.

Sacher Frederic, Jesel Laurence, Borni-Duval Claire, De Precigout Valerie, Lavainne Frédéric, Bourdenx Jean-Philippe, Haddj-Elmrabet Atman, Seigneuric Bruno, Keller Adrien, Ott Julien, Savel Helene, Delmas Yahsou, Bazin-Kara Dorothée, Klotz Nicolas, Ploux Sylvain, Buffler Sébastien, Ritter Philippe, Rondeau Virginie, Bordachar Pierre, Martin Claire, Deplagne Antoine, Reuter Sylvain, Haissaguerre Michel, Gourraud Jean-Baptiste, Vigneau Cécile, Mabo Philippe, Maury Philippe, Hannedouche Thierry, Benard Antoine, Combe Christian

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to identify using implantable loop recorder (ILR) monitoring the mechanisms leading to sudden death (SD) in patients undergoing hemodialysis (HD).

BACKGROUND

SD accounts for 11% to 25% of death in HD patients.

METHODS

Continuous rhythm monitoring was performed using the remote monitoring capability of the ILR device in patients undergoing HD at 8 centers. Clinical, biological, and technical HD parameters were recorded and analyzed.

RESULTS

Seventy-one patients (mean age 65 ± 9 years, 73% men) were included. Left ventricular ejection fraction was <50% in 16%. Twelve patients (17%) had histories of atrial fibrillation or flutter at inclusion. During a mean follow-up period of 21.3 ± 6.9 months, 16 patients died (14% patient-years), 7 (44%) of cardiovascular causes. Four SDs occurred, with progressive bradycardia followed by asystole. The incidence of patients presenting with significant conduction disorder and with ventricular arrhythmia was 14% and 9% patient-years, respectively. In multivariate survival frailty analyses, a higher risk for conduction disorder was associated with plasma potassium >5.0 mmol/l, bicarbonate <22 mmol/l, hemoglobin >11.5 g/dl, pre-HD systolic blood pressure >140 mm Hg, the longer interdialytic period, history of coronary artery disease, previous other arrhythmias, and diabetes mellitus. A higher risk for ventricular arrhythmia was associated with potassium <4.0 mmol/l, no antiarrhythmic drugs, and previous other arrhythmias. With ILR monitoring, de novo atrial fibrillation or flutter was diagnosed in 14 patients (20%).

CONCLUSIONS

ILR may be considered in HD patients prone to significant conduction disorders, ventricular arrhythmia, or atrial fibrillation or flutter to allow early identification and initiation of adequate treatment. Therapeutic strategies reducing serum potassium variability could decrease the rate of SD in these patients. (Implantable Loop Recorder in Hemodialysis Patients [RYTHMODIAL]; NCT01252823).

Для цитирования: Sacher Frederic, Jesel Laurence, Borni-Duval Claire, De Precigout Valerie, Lavainne Frédéric, Bourdenx Jean-Philippe, Haddj-Elmrabet Atman, Seigneuric Bruno, Keller Adrien, Ott Julien, Savel Helene, Delmas Yahsou, Bazin-Kara Dorothée, Klotz Nicolas, Ploux Sylvain, Buffler Sébastien, Ritter Philippe, Rondeau Virginie, Bordachar Pierre, Martin Claire, Deplagne Antoine, Reuter Sylvain, Haissaguerre Michel, Gourraud Jean-Baptiste, Vigneau Cécile, Mabo Philippe, Maury Philippe, Hannedouche Thierry, Benard Antoine, Combe Christian. Cardiac Rhythm Disturbances in Hemodialysis Patients: Early Detection Using an Implantable Loop Recorder and Correlation With Biological and Dialysis Parameters.. JACC. Clinical electrophysiology. 2017. DOI: 10.1016/j.jacep.2017.08.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.