BACKGROUND

During delivery room resuscitation of depressed newborns, provision of appropriate tidal volume (TV) with establishment of functional residual capacity (FRC) is essential for circulatory recovery. Effective positive pressure ventilation (PPV) is associated with a rapid increase in heart rate (HR). The relationship between delivery of TV and HR responses remains unclear.

OBJECTIVES

The study objectives were to determine (1) the relationship between a given TV during initial PPV and HR responses of depressed newborns, and (2) the optimal delivered TV associated with a rapid increase in HR.

METHODS

In a Tanzanian rural hospital, ventilation and ECG signals were recorded during neonatal resuscitation and stored in Neonatal Resuscitation Monitors. Resuscitators without positive end-expiratory pressure were used for PPV. No oxygen was used. Perinatal events were observed and recorded by research assistants.

RESULTS

215 newborns of gestational age 37.3±1.9 weeks and birth weight 3115±579g were included. There was a non-linear relationship between delivered TV and HR increase. TV of 9.3ml/kg produced the largest increase in HR during PPV. Frequent interruptions of PPV sequences to provide stimulation/suctioning occurred in all cases and were associated with further HR increases, especially for newborns with initial HR<100 beats/minute.

CONCLUSIONS

There was a consistent positive relationship between HR increase and delivered TV. The unanticipated finding of a further increase in HR with PPV pauses to provide stimulation/suctioning suggests that most newborns were in primary rather than secondary apnea.

Для цитирования: Linde J E, Schulz J, Perlman J M, Øymar K, Blacy L, Kidanto H, Ersdal H L. The relation between given volume and heart rate during newborn resuscitation.. Resuscitation. 2017. DOI: 10.1016/j.resuscitation.2017.06.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.