MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000070695

Медицинская библиотека · Blood purification · 2003

Liver support--a task for nephrologists? Extracorporeal treatment of a patient with fulminant Wilson crisis.

Manz Tanja, Ochs Andreas, Bisse Emmanuel, Strey Christoph, Grotz Wolfgang

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Patients with Wilson's disease may present with cirrhosis, acute hepatitis or fulminant hepatic failure. Without urgent orthotopic liver transplantation, a fulminant Wilson crisis has a mortality of 100%. We report on an 18-year-old female patient with fulminant hepatic failure due to Wilson crisis.

METHODS

The molecular adsorbent recirculating system (MARS) was used to eliminate albumin-bound toxins and to bridge waiting until an organ became available.

RESULTS

A total of 18 MARS sessions and 4 plasma exchange sessions were performed. Bilirubin levels and hepatic encephalopathy improved under MARS therapy. A total of 75 mg copper was removed until serum copper levels were within the normal range. Copper elimination was measured in 15 MARS treatments, which removed a total of 12.9 mg copper. Four plasma exchange sessions, with a total exchange of 11 liters of plasma, removed 12 mg copper. Urinary copper elimination with penicillamine was 50 mg.

CONCLUSION

MARS was an effective method to stabilize a patient with Wilson crisis, contributed to copper elimination and gained time for liver transplantation. The risk of high-urgency transplantation could be avoided. Liver support was easy in the hands of nephrologists familiar with extracorporeal therapy.

Для цитирования: Manz Tanja, Ochs Andreas, Bisse Emmanuel, Strey Christoph, Grotz Wolfgang. Liver support--a task for nephrologists? Extracorporeal treatment of a patient with fulminant Wilson crisis.. Blood purification. 2003. DOI: 10.1159/000070695.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.