MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2012.12.013

Медицинская библиотека · Journal of biomechanics · 2013

Hyperelastic remodeling in the intrauterine growth restricted (IUGR) carotid artery in the near-term fetus.

Dodson R Blair, Rozance Paul J, Reina-Romo Esther, Ferguson Virginia L, Hunter Kendall S

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A constitutive model for a fiber reinforced hyperelastic material was applied to understand arterial fiber remodeling in a sheep model of Intrauterine Growth Restriction (IUGR). IUGR is associated altered hemodynamics characterized by increased resistance to blood flow in the placenta and elevated fetal arterial pressure and pulsatility. The constitutive model describes the collagen contribution to the mechanics within the arterial wall in both control and IUGR carotid artery through defining the material modulus and the orientation of the microstructure. A sheep model of placental insufficiency induced IUGR (PI-IUGR) was created by exposure of the pregnant ewe to elevated ambient temperatures. Experimental data was collected using pressure-diameter measurements to measure passive compliance in control and PI-IUGR carotid arteries. The constitutive model was optimized to fit the experimental data predicting the material parameters. Specifically, the collagen fiber predicted angle (γ) in the control artery was 49.9° from the circumferential axis while the PI-IUGR was 16.6° with a 23.5% increase in fiber orientation (κ). Quantitative assessment of collagen fiber orientation in secondary harmonic generation images confirmed the shift in orientation between the two groups. Together these suggest vascular remodeling of the ECM fiber orientation plays a major role in arterial stiffening in the PI-IUGR near-term fetal sheep.

Для цитирования: Dodson R Blair, Rozance Paul J, Reina-Romo Esther, Ferguson Virginia L, Hunter Kendall S. Hyperelastic remodeling in the intrauterine growth restricted (IUGR) carotid artery in the near-term fetus.. Journal of biomechanics. 2013. DOI: 10.1016/j.jbiomech.2012.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.