MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-011-4781-1

Медицинская библиотека · Analytical and bioanalytical chemistry · 2011

Semi-automated liquid chromatography-mass spectrometry (LC-MS/MS) method for basic pesticides in wastewater effluents.

Cahill Michael G, Caprioli Giovanni, Stack Mary, Vittori Sauro, James Kevin J

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Effluent from wastewater treatment plants have been identified as an important source of micro-organic contaminants in the environment. An online high-performance liquid chromatography-heated electrospray ionization tandem mass spectrometric method was developed and validated for the determination of basic pesticides in effluent wastewaters. Most available methods for pesticide analysis of wastewater samples are time-consuming, require complex clean-up steps and are difficult to automate. The method developed used a simple solid-phase extraction clean-up for salt and lipid reduction. On-line sample pre-concentration was performed using a reversed phase (C(18)) column, and analytes were separated by back-flushing onto an analytical column (C(8)) with detection using QqQ MS. An option to increase MS resolution was exploited to minimize interference from endogenous compounds in the matrix. A better than unit mass resolution was used (Q1 full width half maximum (FWHM) = 0.2 Da and Q3 FWHM = 0.7 Da), which was as rugged as a unit resolution method, and improved signal/noise and better detection limits were achieved for the targeted basic pesticides. This method was applied to the determination of 11 pesticides, including methoxytriazine, chlorotriazines, chloroacetanilides, phenylurea and carbamate pesticides. The percentage recovery values for these pesticides using the online trapping column were within the range, 73-95%, with relative standard deviation (RSD) values <8.9%. The highest concentrations of these pesticides in wastewater effluents in County Cork, Ireland, were simazine (0.51 μg/L), prometon (0.14 μg/L), diuron (0.21 μg/L) and atrazine (0.19 μg/L).

Для цитирования: Cahill Michael G, Caprioli Giovanni, Stack Mary, Vittori Sauro, James Kevin J. Semi-automated liquid chromatography-mass spectrometry (LC-MS/MS) method for basic pesticides in wastewater effluents.. Analytical and bioanalytical chemistry. 2011. DOI: 10.1007/s00216-011-4781-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.