m+Medelevator.RU
← Поиск публикаций
The Journal of invasive cardiology · 2020

Percutaneous Mitral Valve Repair With MitraClip in Inoperable Patients With Severe Mitral Regurgitation Complicated by Cardiogenic Shock.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Garcia Santiago, Alsidawi Said, Bae Richard, Cavalcante Joao, Eckman Peter, Gössl Mario, Steffen Robert, Sun Benjamin, Schmidt Christian W, Sorajja Paul

Аннотация

BACKGROUND: Severe mitral regurgitation (MR) complicated by cardiogenic shock has high operative mortality. Percutaneous leaflet repair with MitraClip (Abbott Vascular) is a less invasive alternative to surgery. The effectiveness and safety of this approach is unknown.

METHODS: We retrospectively analyzed procedural characteristics of shock patients with severe MR treated with MitraClip in a tertiary, high-volume program (Abbott Northwestern Hospital, Minneapolis, Minnesota) during 2010-2019. The primary outcome of the study was 30-day survival free of significant MR (grade ≤2). One-year mortality was a secondary outcome.

RESULTS: Among 322 patients who underwent MitraClip implantation during the study period, 11 inoperable patients with severe MR and cardiogenic shock were included in this analysis. Mean patient age was 74 ± 11 years and 54% were male. The mechanism of MR was degenerative in 7 patients (63.6%) and functional in 4 patients (36.4%), including 1 post myocardial infarction, 1 with chronic ischemic heart disease, and 2 with end-stage non-ischemic cardiomyopathy. Hemodynamic support with intra-aortic balloon pump was used in 5 patients (45%). The A2-P2 scallop was the more common location for MitraClip insertion, and 27% of patients had >1 clip implanted. Median fluoroscopy time was 18.5 minutes (interquartile range [IQR], 10-22 minutes) and mean postprocedure gradient was 4.5 mm Hg (IQR, 3-5 mm Hg). At 30 days, eight patients (72.7%) were alive with MR grade ≤2. At 1 year, mortality was 66%, and was driven mainly by non-cardiac causes.