MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2298/vsp1202141m

Медицинская библиотека · Vojnosanitetski pregled · 2012

[Determination of morphine, codeine and 6-monoacetylmorphine in saliva of substance-abuse patients using HPLC/MS methods].

Milovanović Vesna, Cirić Biljana, Milenković Jasna, Kilibarda Vesna, Curcić Marijana, Vucinić Slavica, Antonijević Biljana

СтатьяПеревод в очереди

Аннотация

BACKGROUND/AIM: Saliva represents an alternative specimen for substances abuse determination in toxicology. Hence, the aim of this study was to optimize a method for saliva specimen preparation for heroin metabolites, morphine and 6-monoacetylmorphine (6-mam), and codeine determination by liquid chromatography-mass spectrometry (LC/MS), and to apply this method on saliva samples taken from the patients.

METHODS

Saliva specimen was prepared using liqiud/liquid extraction of morphine, codeine and 6-mam by mixture of chloroform and isopropanol (9 : 1; v/v). Extracts were analysed by HPLC/MS technique: separation column Waters Spherisorb 5 microm, ODS2, 4.6 x 100 mm; mobile phase: ammonium acetate : acetonitile (80 : 20; v/v), mobile phase flow rate 0.3 mL/min; mass detection range: 100-400 m/z. Regression and correlation analyses were performed with the probalility level of 0.05. Concentrations of morphine, codeine and 6-mam were determined in saliva samples of the patients with "opiates" in urine identified by the test strips.

RESULTS

Calibration for each analysed substance was done in the concentration range from 0.1 to 1 mg/L and the coefficient of correlation was R2 > 0.99. We obtained following calibration curves: y = 385531x + 14584; y = 398036x + 31542; and y = 524162x - 27105, for morphine, codeine and 6-mam, respectively. Recovery for morphine and codeine determination was 99%, while for 6-mam it was 94%. Limits of detection and quantification of a proposed method were 0.01 mg/L and 0.05 mg/L, respectively. Concentration of morphine in the saliva of the heroin users ranged between 0.54 and 5.82 mg/L, concentration of codeine between 0.05 and 5.33, and 6-mam between 0.01 and 0.68 mg/L. A statistically significant correlation between codeine and 6-mam concentrations was obtained.

CONCLUSION

A proposed HPLC/MS method for morphine, codeine and 6-mam determination in saliva is accurate, simple, cheap and suitable for routine analysis and monitoring of heroin abuse.

Для цитирования: Milovanović Vesna, Cirić Biljana, Milenković Jasna, Kilibarda Vesna, Curcić Marijana, Vucinić Slavica, Antonijević Biljana. [Determination of morphine, codeine and 6-monoacetylmorphine in saliva of substance-abuse patients using HPLC/MS methods].. Vojnosanitetski pregled. 2012. DOI: 10.2298/vsp1202141m.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.