MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12265-019-09890-5

Медицинская библиотека · Journal of cardiovascular translational research · 2019

The Influence of Aortic Valve Obstruction on the Hyperemic Intracoronary Physiology: Difference Between Resting Pd/Pa and FFR in Aortic Stenosis.

Scarsini Roberto, De Maria Giovanni L, Di Gioia Giuseppe, Kotronias Rafail A, Aurigemma Cristina, Zimbardo Giuseppe, Burzotta Francesco, Leone Antonio M, Pesarini Gabriele, Trani Carlo, Crea Filippo, Kharbanda Rajesh K, De Bruyne Bernard, Barbato Emanuele, Banning Adrian, Ribichini Flavio

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The reliability of fractional flow reserve (FFR) in aortic stenosis (AS) has been questioned because of the uncertain response to vasodilators. A retrospective multicenter cohort of 114 AS patients who underwent coronary physiology assessment was compared with 154 controls before and after propensity matching adjustment. The difference between resting distal coronary vs aortic pressure ratio (Pd/Pa) and FFR (ΔPd/Pa-FFR) was tested against the severity of AS. ΔPd/Pa-FFR was not influenced by the severity of AS in terms of aortic valve area (r = - 0.02, p = 0.83) and gradient (r = - 0.05, p = 0.64) or by the left ventricle hypertrophy (r = - 0.03, p = 0.88). Conversely, ΔPd/Pa-FFR was influenced by the presence of diabetes (r = - 0.24, p = 0.005), peripheral vascular disease (r = - 0.16, p = 0.047), and chronic kidney disease (r = - 0.19, p = 0.03). No significant difference was observed in the ΔPd/Pa-FFR between patients with AS and matched controls. Further studies are warranted to validate the FFR-guided revascularization in patients with AS.

Для цитирования: Scarsini Roberto, De Maria Giovanni L, Di Gioia Giuseppe, Kotronias Rafail A, Aurigemma Cristina, Zimbardo Giuseppe, Burzotta Francesco, Leone Antonio M, Pesarini Gabriele, Trani Carlo, Crea Filippo, Kharbanda Rajesh K, De Bruyne Bernard, Barbato Emanuele, Banning Adrian, Ribichini Flavio. The Influence of Aortic Valve Obstruction on the Hyperemic Intracoronary Physiology: Difference Between Resting Pd/Pa and FFR in Aortic Stenosis.. Journal of cardiovascular translational research. 2019. DOI: 10.1007/s12265-019-09890-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.