MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/0284186x.2013.813074

Медицинская библиотека · Acta oncologica (Stockholm, Sweden) · 2013

Quantification of radiation-induced lung damage with CT scans: the possible benefit for radiogenomics.

De Ruysscher Dirk, Sharifi Hoda, Defraene Gilles, Kerns Sarah L, Christiaens Melissa, De Ruyck Kim, Peeters Stéphanie, Vansteenkiste Johan, Jeraj Robert, Van Den Heuvel Frank, van Elmpt Wouter

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Radiation-induced lung damage (RILD) is an important problem. Although physical parameters such as the mean lung dose are used in clinical practice, they are not suited for individualised radiotherapy. Objective, quantitative measurements of RILD on a continuous instead of on an ordinal, semi-quantitative, semi-subjective scale, are needed.

METHODS

Hounsfield unit (HU) changes before versus three months post-radiotherapy were correlated per voxel with the radiotherapy dose in 95 lung cancer patients. Deformable registration was used to register pre- and post-CT scans and the density increase was quantified for various dose bins. The dose-response curve for increased HU was quantified using the slope of a linear regression (HU/Gy). The end-point for the toxicity analysis was dyspnoea ≥ grade 2.

RESULTS

Radiation dose was linearly correlated with the change in HU (mean R(2) = 0.74 ± 0.28). No differences in HU/Gy between groups treated with stereotactic radiotherapy, conventional radiotherapy alone, sequential or concurrent chemo- radiotherapy were observed. In the whole patient group, 33/95 (34.7%) had dyspnoea ≥ G2. Of the 48 patients with a HU/Gy below the median, 16 (33.3%) developed dyspnoea ≥ G2, while in the 47 patients with a HU/Gy above the median, 17 (36.1%) had dyspnoea ≥ G2 (not significant). Individual patients showed a nearly 21-fold difference in radiosensitivity, with HU/Gy ranging from 0 to 10 HU/Gy.

CONCLUSIONS

HU changes identify objectively the whole range of individual radiosensitivity on a continuous, quantitative scale. CT density changes may allow more robust and accurate radiogenomics studies.

Для цитирования: De Ruysscher Dirk, Sharifi Hoda, Defraene Gilles, Kerns Sarah L, Christiaens Melissa, De Ruyck Kim, Peeters Stéphanie, Vansteenkiste Johan, Jeraj Robert, Van Den Heuvel Frank, van Elmpt Wouter. Quantification of radiation-induced lung damage with CT scans: the possible benefit for radiogenomics.. Acta oncologica (Stockholm, Sweden). 2013. DOI: 10.3109/0284186x.2013.813074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.