BACKGROUND

The 3-Minute Diagnostic Interview for Confusion Assessment Method-Defined Delirium (3D-CAM) is an instrument specially developed for the assessment of delirium in general wards, with high reported sensitivity and specificity. However, the use of the 3D-CAM by bedside nurses in routine practice showed relatively poor usability, with multiple human errors during assessment.

OBJECTIVE

This study aimed to develop a mobile app-based delirium assessment tool based on the 3D-CAM and evaluate its usability among older patients by bedside nurses.

METHODS

The Delirium Assessment Tool With Decision Support Based on the 3D-CAM (3D-DST) was developed to address existing issues of the 3D-CAM and optimize the assessment process. Following a randomized crossover design, questionnaires were used to evaluate the usability of the 3D-DST among older adults by bedside nurses. Meanwhile, the performances of both the 3D-DST and the 3D-CAM paper version, including the assessment completion rate, time required for completing the assessment, and the number of human errors made by nurses during assessment, were recorded, and their differences were compared.

RESULTS

The 3D-DST included 3 assessment modules, 9 evaluation interfaces, and 16 results interfaces, with built-in reminders to guide nurses in completing the delirium assessment. In the usability testing, a total of 432 delirium assessments (216 pairs) on 148 older adults were performed by 72 bedside nurses with the 3D-CAM paper version and the 3D-DST. Compared to the 3D-CAM paper version, the mean usability score was significantly higher when using the 3D-DST (4.35 vs 3.40; P<.001). The median scores of the 6 domains of the satisfactory evaluation questionnaire for nurses using the 3D-CAM paper version and the 3D-DST were above 2.83 and 4.33 points, respectively (P<.001). The average time for completing the assessment reduced by 2.1 minutes (4.4 vs 2.3 min; P<.001) when the 3D-DST was used.

CONCLUSIONS

This study demonstrated that the 3D-DST significantly improved the efficiency of delirium assessment and was considered highly acceptable by bedside nurses.

Для цитирования: Wang Jiamin, Ji Meihua, Han Yuan, Wu Ying. Development and Usability Testing of a Mobile App-Based Clinical Decision Support System for Delirium: Randomized Crossover Trial.. JMIR aging. 2024. DOI: 10.2196/51264.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.