MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13019-018-0788-4

Медицинская библиотека · Journal of cardiothoracic surgery · 2018

Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China.

Akuffu Armah M, Zhao Haige, Zheng Junnan, Ni Yiming

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Prosthesis-patient mismatch (PPM) may affect the clinical outcomes of patients undergoing mitral valve replacement (MVR) surgery. We aimed to investigate the incidence of PPM of the mitral position in our center and analyze the possible predictors of PPM as well as its effect on short-term outcomes.

METHODS

We retrospectively examined all consecutive patients with isolated or concomitant MVR at our center from 2013 to 2015. PPM was defined as an indexed effective orifice area (iEOA) of ≤1.2 cm2/m2. After inclusion and exclusion, a total of 1067 patients were analyzed. The baseline information were collected and compared between the two groups. Multivariate logistic regression analysis was conducted to determine the preoperative predictors of PPM as well as the effect of PPM on early mortality.

RESULTS

A total of 1067 patients were included in the study. PPM was detected in 15.9% of the patients while 12 patients (1.12%) met the criteria for severe PPM. Patients with PPM compared to the non-PPM patients had higher age, larger body surface area and were more likely to be male and obese. Logistic regression analysis showed that higher age, larger BSA, bioprosthesis and smaller left ventricle end-diastolic diameter were predictors of PPM. There were no significant differences between the PPM and non-PPM groups regarding post-operative complications. Logistic regression analysis showed that PPM was not a risk factor of short-term mortality (P = 0.654). Also, there were no significant differences regarding short-/mid-term heart function between the PPM and non PPM groups (P = 0.902).

CONCLUSIONS

Our results demonstrated that higher age, bioprosthesis, larger BSA and smaller left ventricle size were associated with mitral PPM. However, PPM was not associated with poorer early outcomes after MVR surgery. In eastern of China, the prevalence of mitral valve stenosis is high; therefore, whether the standard PPM criteria are suitable for patients of this district needs to be further verified.

Для цитирования: Akuffu Armah M, Zhao Haige, Zheng Junnan, Ni Yiming. Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China.. Journal of cardiothoracic surgery. 2018. DOI: 10.1186/s13019-018-0788-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.