m+Medelevator.RU
← Поиск публикаций
Journal of infection and public health · 2021

Development and validation of an in-house, low-cost SARS-CoV-2 detection assay.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Alhamlan Fatimah S, Al-Qahtani Ahmed A, Bakheet Dana M, Bohol Marie F, Althawadi Sahar I, Mutabagani Maysoon S, Almaghrabi Reem S, Obeid Dalia A

Аннотация

BACKGROUND: One major challenge for detecting the virus that causes COVID-19 is commercial SARS-CoV-2 testing kit or reagent availability. To allow every laboratory or hospital access to an in-house assay, we developed a low-cost SARS-CoV-2 detection assay protocol using in-house primers and reagents/equipment on hand in most biology or diagnostic laboratories: a SYBR Green-based RT-PCR. RNA extraction has also become a major bottleneck due to limited supplies and the required labor. Thus, we validated an alternative RNA extraction protocol.

METHODS: We designed and synthesized in-house primers according to SARS-CoV-2 genome sequences retrieved from GISAID database. One hundred and ninety patient samples were collected by nasopharyngeal swab, coded, and used to develop and validate the assay protocol. RNA extraction was performed using TRI reagent-based RNA protocol to inactivate the virus; thus, testing was conducted in a conventional biosafety level 2 laboratory.

RESULTS: The sensitivity and specificity of the primers were evaluated using 190 patient samples previously tested for SARS-CoV-2. The positive amplicons were sequenced to confirm the results. The assay protocol was developed, and the specificity of each RT-PCR product was confirmed using melting curve analyses. Of 190 samples, the SYBR Green-based RT-PCR assay detected SARS-CoV-2 target genes in 88 samples, with no false-positive results. These findings indicate that the sensitivity of our assay was 97.7% and specificity of 100% with those of the diagnostic laboratory that tested the same samples using a Rotor-Gene PCR cycler with an Altona Diagnostics SARS-CoV-2 kit (R2 = 0.89).

CONCLUSIONS: These approaches are reliable, repeatable, specific, sensitive, simple, and low-cost tools for the detection of SARS-CoV-2 in a conventional biosafety level 2 laboratory, offering alternative approaches when commercial kits are unavailable or not affordable.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты