Медицинская библиотека · Transplantation · 2010

Reduced ischemia-reoxygenation injury in rat intestine after luminal preservation with a tailored solution.

Roskott Anne Margot, Nieuwenhuijs Vincent B, Leuvenink Henri G D, Dijkstra Gerard, Ottens Petra, de Jager Marina H, Gonalves Dias Pereira Patricia, Fidler Vaclav, Groothuis Geny M M, Ploeg Rutger J, de Graaf Inge A M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The intestine is extremely sensitive to ischemic preservation and reoxygenation injury. Current vascular perfusion and cold storage with University of Wisconsin (UW) solution neglect the intestinal lumen and the ongoing mucosal metabolism during hypothermia. This study was designed to test the effects of luminal preservation with an alternative preservation solution in addition to the common vascular flush with UW solution on graft viability after preservation and ex vivo reoxygenation.

METHODS

Rat intestine was preserved on ice for 6 hr in UW solution or Williams Medium E with additional buffering, impermeants, and a colloid (WMEplus) after being stapled or after flushing and filling the lumen with the respective preservation solution. Tissue slices were prepared from fresh and preserved intestines and were incubated with oxygen for 6 hr at 37°C to assess the viability after reoxygenation.

RESULTS

Directly after preservation, histologic damage was mild and unaffected by preservation strategy. Contrary to luminal preservation, closed preservation resulted in significantly decreased ATP levels compared with control. Reoxygenation aggravated damage and revealed differences between the strategies. Luminal preservation better maintained the ATP levels and histologic integrity (vs. closed preservation) for both solutions. Histomorphologic integrity was superior after preservation with WMEplus (vs. UW solution). Expression of stress responsive genes was least up-regulated in the slices from tissue preserved luminally with WMEplus.

CONCLUSIONS

In conclusion, preservation and reoxygenation injury can be attenuated by luminal preservation with WMEplus.

Для цитирования: Roskott Anne Margot, Nieuwenhuijs Vincent B, Leuvenink Henri G D, Dijkstra Gerard, Ottens Petra, de Jager Marina H, Gonalves Dias Pereira Patricia, Fidler Vaclav, Groothuis Geny M M, Ploeg Rutger J, de Graaf Inge A M. Reduced ischemia-reoxygenation injury in rat intestine after luminal preservation with a tailored solution.. Transplantation. 2010. DOI: 10.1097/tp.0b013e3181ebf796.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.