DOI 10.2174/2211738511666230328181120
The Sustained-released Polylactic Co-glycolic Acid Nanoparticles Loaded with Chlorhexidine as Antibacterial Agents Inside the Dental Implant Fixture.
Аннотация
INTRODUCTION
Titanium-based implants are widely used due to their good biocompatibility and high corrosion resistance. Infections after implant placement are the main reason for the failure of implant treatment. Some recent studies have also shown that microbial contamination can occur at the implant-abutment level in implants with healthy or diseased surrounding tissue. The purpose of this study is to investigate the antibacterial effect of slow-release nanoparticles of polylactic co-glycolic acid (PLGA) loaded with chlorhexidine (CHX) inside the implant fixture.
MATERIALS AND
METHODS
Thirty-six implants in three groups were examined in the bacterial culture environment. In the first group, PLGA/CHX nanoparticles; in the second group, the negative control group (distilled water) and in the third group, the positive control groups (chlorhexidine) were used. The bacterial suspensions, including Escherichia coli ATCC: 25922, Staphylococcus aureus ATCC: 6538 and Enterococcus faecalis ATCC: 29212 were used to investigate the antimicrobial effect of the prepared nanoparticles.
RESULTS
The results showed that the use of PLGA/CHX nanoparticles significantly inhibited the growth of all three bacteria. Nanoparticles loaded with chlorhexidine had a significant decrease in the growth rate of all three bacteria compared to chlorhexidine and water. The lowest bacterial growth rate was observed in the Enterococcus faecalis/PLGA nanoparticles group, and the highest bacterial growth rate was observed in the Staphylococcus aureus/H2O group.
CONCLUSION
The current study showed that the use of PLGA/CHX nanoparticles could significantly inhibit the growth of all three bacteria. Of course, the current study was conducted in vitro, and to obtain clinical results, we need to conduct a study on human samples. In addition, the results of this study showed that the chemical antimicrobial materials could be used in low concentrations and in a sustained- released manner in cases of dealing with bacterial infections, which can lead to better and targeted performance as well as reduce possible side effects.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.