DOI 10.1016/j.chemosphere.2021.130799

Медицинская библиотека · Chemosphere · 2021

The relevant role of ion mobility separation in LC-HRMS based screening strategies for contaminants of emerging concern in the aquatic environment.

Celma Alberto, Ahrens Lutz, Gago-Ferrero Pablo, Hernández Félix, López Francisco, Lundqvist Johan, Pitarch Elena, Sancho Juan Vicente, Wiberg Karin, Bijlsma Lubertus

СтатьяПеревод в очереди

Аннотация

Ion mobility separation (IMS) coupled to high resolution mass spectrometry (IMS-HRMS) is a promising technique for (non-)target/suspect analysis of micropollutants in complex matrices. IMS separates ionized compounds based on their charge, shape and size facilitating the removal of co-eluting isomeric/isobaric species. Additionally, IMS data can be translated into collision cross-section (CCS) values, which can be used to increase the identification reliability. However, IMS-HRMS for the screening of contaminants of emerging concern (CECs) have been scarcely explored. In this study, the role of IMS-HRMS for the identification of CECs in complex matrices is highlighted, with emphasis on when and with which purpose is of use. The utilization of IMS can result in much cleaner mass spectra, which considerably facilitates data interpretation and the obtaining of reliable identifications. Furthermore, the robustness of IMS measurements across matrices permits the use of CCS as an additional relevant parameter during the identification step even when reference standards are not available. Moreover, an effect on the number of true and false identifications could be demonstrated by including IMS restrictions within the identification workflow. Data shown in this work is of special interest for environmental researchers dealing with the detection of CECs with state-of-the-art IMS-HRMS instruments.

Для цитирования: Celma Alberto, Ahrens Lutz, Gago-Ferrero Pablo, Hernández Félix, López Francisco, Lundqvist Johan, Pitarch Elena, Sancho Juan Vicente, Wiberg Karin, Bijlsma Lubertus. The relevant role of ion mobility separation in LC-HRMS based screening strategies for contaminants of emerging concern in the aquatic environment.. Chemosphere. 2021. DOI: 10.1016/j.chemosphere.2021.130799.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.