m+Medelevator.RU
← Поиск публикаций
PloS one · 2021

Real-life clinical sensitivity of SARS-CoV-2 RT-PCR test in symptomatic patients.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kortela Elisa, Kirjavainen Vesa, Ahava Maarit J, Jokiranta Suvi T, But Anna, Lindahl Anna, Jääskeläinen Anu E, Jääskeläinen Annemarjut J, Järvinen Asko, Jokela Pia, Kallio-Kokko Hannimari, Loginov Raisa, Mannonen Laura, Ruotsalainen Eeva, Sironen Tarja, Vapalahti Olli, Lappalainen Maija, Kreivi Hanna-Riikka, Jarva Hanna, Kurkela Satu, Kekäläinen Eliisa

Аннотация

BACKGROUND: Understanding the false negative rates of SARS-CoV-2 RT-PCR testing is pivotal for the management of the COVID-19 pandemic and it has implications for patient management. Our aim was to determine the real-life clinical sensitivity of SARS-CoV-2 RT-PCR.

METHODS: This population-based retrospective study was conducted in March-April 2020 in the Helsinki Capital Region, Finland. Adults who were clinically suspected of SARS-CoV-2 infection and underwent SARS-CoV-2 RT-PCR testing, with sufficient data in their medical records for grading of clinical suspicion were eligible. In addition to examining the first RT-PCR test of repeat-tested individuals, we also used high clinical suspicion for COVID-19 as the reference standard for calculating the sensitivity of SARS-CoV-2 RT-PCR.

RESULTS: All 1,194 inpatients (mean [SD] age, 63.2 [18.3] years; 45.2% women) admitted to COVID-19 cohort wards during the study period were included. The outpatient cohort of 1,814 individuals (mean [SD] age, 45.4 [17.2] years; 69.1% women) was sampled from epidemiological line lists by systematic quasi-random sampling. The sensitivity (95% CI) for laboratory confirmed cases (repeat-tested patients) was 85.7% (81.5-89.1%) inpatients; 95.5% (92.2-97.5%) outpatients, 89.9% (88.2-92.1%) all. When also patients that were graded as high suspicion but never tested positive were included in the denominator, the sensitivity (95% CI) was: 67.5% (62.9-71.9%) inpatients; 34.9% (31.4-38.5%) outpatients; 47.3% (44.4-50.3%) all.

CONCLUSIONS: The clinical sensitivity of SARS-CoV-2 RT-PCR testing was only moderate at best. The relatively high false negative rates of SARS-CoV-2 RT-PCR testing need to be accounted for in clinical decision making, epidemiological interpretations, and when using RT-PCR as a reference for other tests.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты