BACKGROUND

Although computer navigation has improved component alignment in total knee arthroplasty (TKA), radiographic outliers are reported with a wide range in literature even using this technique. We hypothesized that the postoperative malalignment after computer-navigated TKA was partially derived from the inherent problems with two-dimensional (2D) measurement such as inaccuracies in measurement due to the knee position during the radiographic examination and the direction of the X-ray beam. We therefore conducted this study to determine how often knees with malalignment on 2D imaging were truly mal-aligned on three-dimensional (3D) reconstructed imaging.

METHODS

Sixty-two computer-navigated primary TKAs performed in 47 patients were included in this study. In all cases, a weight-bearing long-leg radiograph was obtained after TKA. 3D measurements were performed for outliers 2° or more in coronal alignment of the femoral or tibial component.

RESULTS

For the 18 femoral mal-aligned components on 2D imaging, eight (44.4%) were not truly mal-aligned on 3D imaging (P = 0.0014). For the eight tibial mal-aligned components on 2D imaging, all knees (100%) were not truly mal-aligned on 3D imaging (P < 0.0001).

CONCLUSIONS

A considerable number of the false malalignments were included on 2D measurement. Postoperative component alignment in the computer-navigated TKA might be much better than previously reported.

Для цитирования: Tsukeoka Tadashi, Tsuneizumi Yoshikazu. False malalignment after computer-navigated total knee arthroplasty.. The Knee. 2021. DOI: 10.1016/j.knee.2021.03.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.