MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2014.05.048

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2014

Development and validation of an LC-MS/MS method for determination of the L-type voltage-gated calcium channel/NMDA receptor antagonist NGP1-01 in mouse serum.

Jogiraju Harini, Zhou Xiang, Gobburi Ashta Lakshmi Prasad, Pedada Kiran K, Geldenhuys Werner J, Van der Schyf Cornelis J, Crish Samuel D, Anderson David J

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

NGP1-01 (8-benzylamino-8,11-oxapentacyclo[5.4.0.0(2,6).0(3,10).0(5,9)]undecane) is a heterocyclic cage compound with multifunctional calcium channel blocking activity that has been demonstrated to be neuroprotective in several neurodegenerative models. A sensitive internal standard LC-MS/MS method was developed and validated to quantify NGP1-01 in mouse serum. The internal standard (IS) was 8-(2-phenylethylamino)-8,11-oxapentacyclo[5.4.0.0(2,6).0(3,10).0(5,9)]undecane. Sample preparation involved a protein precipitation procedure by addition of acetonitrile. Chromatographic separation was carried out on a Phenomenex Kinetex phenyl-hexyl column (100 mm×2.1mm, 2.6 μm) employing a gradient (45% isocratic 3 min, 45-95% linear gradient 6 min, 95% isocratic 3 min) of an elution mobile phase of 5mM ammonium acetate in 100% acetonitrile mixing with an application mobile phase of 5mM ammonium acetate in 2% acetonitrile. Detection was achieved by a QTrap 5500 mass spectrometer (AB Sciex) employing electrospray ionization in the positive mode with multiple-reaction-monitoring (MRM) for NGP1-01 (m/z 266→91) and IS (m/z 280→105). The method validation was carried out in accordance with Food and Drug Administration (FDA) guidelines. The method had a linear range of at least 0.5-50 ng/mL with a correlation coefficient 0.999. The intra-assay and inter-assay precisions (%CV) were equal to or within the range of 1.0-4.3% and the accuracies (% relative error) equal to or within -2.5% to 3.4%. The analyte was stable for at least 2 months at -20°C, for at least 8h at room temperature and for at least three freeze-thaw cycles. The extraction recovery was 94.9 to 105.0%, with a %CV ≤ 9.5%. The technique was found to be free of any matrix effects as determined by experiments involving five different lots of mouse serum. Cross-talk interferences were not present. Two different gradient slope chromatography runs were done on dosed mouse serum samples to assess a possible positive error in peak area determination from in-source fragmentation of metabolites generating the same MRM transitions as the parent drug or IS. No such interference was found in the NGP1-01 peak, while a minor interference was identified in the IS peak. The optimized method was applied to the measurement of NGP1-01 in serum of dosed mice.

Для цитирования: Jogiraju Harini, Zhou Xiang, Gobburi Ashta Lakshmi Prasad, Pedada Kiran K, Geldenhuys Werner J, Van der Schyf Cornelis J, Crish Samuel D, Anderson David J. Development and validation of an LC-MS/MS method for determination of the L-type voltage-gated calcium channel/NMDA receptor antagonist NGP1-01 in mouse serum.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2014. DOI: 10.1016/j.jchromb.2014.05.048.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.