[Compliance with continuous positive airway pressure therapy in patients with sleep apnea/hypopnea syndrome].

Сравнительное исследованиеАннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gallego Claudio W, Dibur Eduardo, Salomone César, Di Bartolo Carlos G

Аннотация

Predictive factors and compliance level were evaluated in a group of patients with sleep apnea syndrome under CPAP treatment, assessing side effects and equipment condition: silicone interface (SI), mask-conectors (M-C), air tube (AT) and head strap (HS). Patients with >3mo treatment were included, clock counter reading was registered at the beginning, 2 and 4 mo. Patients were considered compliant (C+) when usage was >4h/day and >5day/week. Of 46 patients (male 34; age 62 +/- 9years; BMI 33 +/- 7kg/m2; AHI 38 +/- 18/h; time of therapy 2.1 +/- 1.7years; CPAP 9 +/- 1.4 cmH2O), 34 had a clock counter and 24 (71%) were C+. Initial symptoms included: somnolence (65%), snoring (39%), bed-partner witnessed apneas (28%). Comparing C+ and C- we didn't find significant difference in age, BMI, CPAP pressure, length of therapy, AHI and pre-treatment Epworth classification. Referred vs. measured time of use in C+ and C- were 6.6 +/- 1 vs. 6.1 +/- 1 h/d (p=0.02) and 5.6 +/- 1 vs. 2.4 +/- 1 h/d (p<0.005). Compliant patients reported more resolution of somnolence (p<0.005) and nocturia (p<0.05), lower post CPAP Epworth (p<0.05), more frequent somnolence as initial symptom (p<0.05) and a higher education level (p=0.01). Side effects (SE) (n=45): dry mouth 36%, nasal congestion 27%, sleep disruption 11%, CPAP noisy 9%, dry nose, rhinorrhea and skin irritation 7%. Twenty seven percent of patients reduced the CPAP use because of the SE. Correction strategies included: humidifier, nasal steroid, surgery or infiltration of turbinates. Comparing the condition of SI, M-C, AT and HS between < or =1 vs. >1year of use, we observed a lower percentage of fine elements (87 to 44%, 74 to 44%, 83 to 44%, 91 to 78%, respectively). Most common defects included stiffness of SI, cracks in SI, M-C and AT, loose conexions. The study confirms the importance of objective monitoring in patients with CPAP. Side effects and equipment condition require special attention because this could affect an effective treatment.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты