Flexible optically stimulated luminescence band for 1D in vivo radiation dosimetry.

Kim Tae Jin, Jung Kyung Oh, Fahimian Benjamin, Pratx Guillem

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In vivo dosimetry helps ensure the accuracy of radiation treatments. However, standard techniques are only capable of point sampling, making it difficult to accurately measure dose variation along curved surfaces in a continuous manner. The purpose of this work is to introduce a flexible dosimeter band and validate its performance using pre-clinical and clinical x-ray sources. Dosimeter bands were fabricated by uniformly mixing BaFBr:Eu storage phosphor powders into a silicone based elastomer. An optical readout device with dual-wavelength excitation was designed and built to correct for non-uniform phosphor density and extract accurate dose information. Results demonstrated significant correction of the non-uniform readout signal and excellent dose linearity up to 8 Gy irradiation using a pre-clinical 320 kV x-ray system. Beam profile measurements were demonstrated over a long distance of ~30 cm by placing multiple dosimeters in a single line and stitching the results. The performance of the dosimeters was also tested using a clinical linear accelerator (6 MV) and compared to radiochromic film. Once bias corrected, the bands displayed a linear dose response over the 1.02-9.36 Gy range (R 2  >  0.99). The proposed system can be further improved by reducing the size of the readout beam and by more uniformly mixing the phosphor powder with the elastomer. We expect this technique to find application for large-field treatments such as total-skin irradiation and total-body irradiation.

Для цитирования: Kim Tae Jin, Jung Kyung Oh, Fahimian Benjamin, Pratx Guillem. Flexible optically stimulated luminescence band for 1D in vivo radiation dosimetry.. Physics in medicine and biology. 2018. DOI: 10.1088/1361-6560/aad319.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.