MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1365-2591.2008.01532.x

Медицинская библиотека · International endodontic journal · 2009

Effectiveness of different laser systems to kill Enterococcus faecalis in aqueous suspension and in an infected tooth model.

Meire M A, De Prijck K, Coenye T, Nelis H J, De Moor R J G

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To assess the antibacterial action of laser irradiation (Nd:YAG, KTP), photo activated disinfection (PAD) and 2.5% sodium hypochlorite (NaOCl) on Enterococcus faecalis, in an aqueous suspension and in an infected tooth model.

METHODOLOGY: Root canals of 60 human teeth with single straight canals were prepared to apical size 50, autoclaved, inoculated with an E. faecalis suspension and incubated for 48 h. They were randomly allocated to four treatment and one control groups. After treatment, the root canals were sampled by flushing with physiological saline, and the number of surviving bacteria in each canal was determined by plate count and solid phase cytometry. The same experimental or control treatments were completed on aqueous suspensions of E. faecalis, and the number of surviving bacteria was determined in the same way.

RESULTS

In aqueous suspension, PAD and NaOCl resulted in a significant reduction in the number of E. faecalis cells (P < 0.001), whilst Nd:YAG or KTP had no effect. In the infected tooth model, only the PAD and NaOCl treated teeth yielded significantly different results relative to the untreated controls (P < 0.001).

CONCLUSIONS

The laser systems as well as PAD were less effective than NaOCl in reducing E. faecalis, both in aqueous suspension and in the infected tooth model.

Для цитирования: Meire M A, De Prijck K, Coenye T, Nelis H J, De Moor R J G. Effectiveness of different laser systems to kill Enterococcus faecalis in aqueous suspension and in an infected tooth model.. International endodontic journal. 2009. DOI: 10.1111/j.1365-2591.2008.01532.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.