BACKGROUND

Human herpes simplex virus type 1 (HSV-1) and type 2 (HSV-2) are responsible for a plethora of human diseases, of which cutaneous and mucocutaneous infections are the most prevalent. In its most severe form, HSV infection can cause meningitis/encephalitis. We compared the Luminex ARIES HSV 1&2 assay (Luminex Corp., Austin, TX, USA), an automated sample-to-result molecular solution, to two non-automated HSV DNA assays.

METHODS

A total of 116 artificial controls were used to determine the analytical performance of the ARIES assay. Controls were prepared by spiking universal transport medium (UTM) and cerebrospinal fluid (CSF) samples from patients who tested negative for HSV by an in-house HSV-1 and -2 DNA assay with reference materials (SeraCare Life Sciences, MA, USA; ZeptoMetrix Corp., MA, USA). Another 117 clinical samples were then used to compare the clinical performance of the ARIES assay with those of an in-house assay and the FTD Neuro 9 assay (Fast Track Diagnostics, Junglinster, Luxembourg).

RESULTS

The analytical sensitivity (95% limit of detection) of the ARIES assay was 318 copies/mL (UTM samples) and 935 copies/mL (CSF samples) for HSV-1 strain 96 and 253 copies/mL (UTM samples) and 821 copies/mL (CSF samples) for HSV-2 strain 09. No cross-reactivity was observed in samples spiked with 14 non-HSV microorganisms. Compared with the reference result (agreement between the in-house and FTD Neuro 9 results), the ARIES assay had overall concordance rates of 98.2% (111/113) and 100% (113/113) for HSV-1 and HSV-2, respectively.

CONCLUSIONS

The ARIES assay appears to be an excellent alternative for rapid detection and differentiation of HSV in skin and genital infections, meningitis, and encephalitis.

Для цитирования: Lee Chun Kiat, Chai Chean Nee, Capinpin Sharah Mae, Ang Alynn, Ng Sau Yoke, Lee Peak Ling, Ng Christopher Wai Siong, Yan Gabriel, Lee Hong Kai, Chiu Lily Lily, Jureen Roland, Yan Benedict, Loh Tze Ping. Evaluation of the Luminex ARIES HSV 1&2 Assay and Comparison with the FTD Neuro 9 and In-house Real-Time PCR Assays for Detecting Herpes Simplex Viruses.. Annals of laboratory medicine. 2018. DOI: 10.3343/alm.2018.38.5.440.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.