m+Medelevator.RU
← Поиск публикаций
Diabetic medicine : a journal of the British Diabetic Association · 2016

One-hour post-load plasma glucose level during the OGTT predicts mortality: observations from the Israel Study of Glucose Intolerance, Obesity and Hypertension.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bergman M, Chetrit A, Roth J, Dankner R

Аннотация

AIMS: The relationship between 1- and 2-h glucose levels following an oral glucose tolerance test (OGTT) and long-term mortality was evaluated.

METHODS: Over a 33-year period, 2138 individuals were followed for all-cause mortality. Fasting and post-OGTT glucose parameters categorized the cohort according to baseline glycaemic status. Four categories were established according to 1- and 2-h glucose levels (in mmol/l): group A = 1 h ≤ 8.8 and 2 h < 7.8; group B = 1 h > 8.6 and 2 h < 7.8; group C = 1 h ≤ 8.6 and 2 h = 7.8-11.1 (impaired glucose tolerance); group D = 1 h > 8.6 and 2 h = 7.8-11.1 (impaired glucose tolerance). Individuals with diabetes at baseline were excluded from the cohort.

RESULTS: By August 2013, 51% of the study cohort had died. The worst prognosis occurred in group D (73.8% mortality), followed by groups C (67.5%), B and A (57.9% and 41.6%, respectively). When the 2-h glucose value is 'normal' (< 7.8 mmol/l), the 1-h glucose value > 8.6 mmol/l is an important predictor of mortality (28% increased risk) compared with group A, controlling for sex, age, smoking, BMI, systolic and diastolic blood pressures. A gradual increased hazard for mortality was seen by study group (hazard ratio = 1.28, 1.60 and 1.76, for groups B, C and D, respectively; group A = reference).

CONCLUSIONS: A 1-h glucose value > 8.6 mmol/l predicts mortality even when the 2-h level is < 7.8 mmol/l. However, when the 2-h level is in the impaired glucose tolerance range, the hazard for mortality rises significantly independent of the 1-h value. Individuals at risk for developing diabetes could be identified earlier using the 1-h threshold value of 8.6 mmol/l, which could avert progression to diabetes and increased mortality.‬.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты