A semi-automated 96-well plate method for the simultaneous determination of oral contraceptives concentrations in human plasma using ultra performance liquid chromatography coupled with tandem mass spectrometry.

Licea-Perez Hermes, Wang Sherry, Bowen Chester L, Yang Eric

СтатьяПеревод в очереди

Аннотация

Two semi-automated, relatively high throughput methods using ultra performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) were developed for the simultaneous determination of ethinyl estradiol (EE) in combination with either 19-norethindrone (NE) or levonorgestrel (LN) in human plasma. Using 300 microL plasma, the methods were validated over the concentration ranges of 0.01-2 ng/mL and 0.1-20 ng/mL for EE and NE (or LN), respectively. The existing methods for the determination of the oral contraceptives in human plasma require large volumes of plasma (> or =500 microL), and sample extraction is labor-intensive. The LC run time is at least 6 min, enabling analysis of only about 100 samples a day. In the present work the throughput was greatly improved by employing a semi-automated sample preparation process involving liquid-liquid extraction and derivatization with dansyl chloride followed by UPLC separation on a small particle size column achieving a run time of 2.7 min. The validation and actual sample analysis results show that both methods are rugged, precise, accurate, and well suitable to support pharmacokinetic studies where approximately 300 samples can be extracted and analyzed in a day.

Для цитирования: Licea-Perez Hermes, Wang Sherry, Bowen Chester L, Yang Eric. A semi-automated 96-well plate method for the simultaneous determination of oral contraceptives concentrations in human plasma using ultra performance liquid chromatography coupled with tandem mass spectrometry.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2007. DOI: 10.1016/j.jchromb.2006.12.052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.