Long-term outcomes and patient satisfaction after artificial urinary sphincter implantation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Deruyver Yves, Schillebeeckx Charlotte, Beels Elodie, De Ridder Dirk, Van der Aa Frank

Аннотация

PURPOSE: To evaluate long-term functional outcomes of artificial urinary sphincter implantation in men for the treatment of stress urinary incontinence.

MATERIALS AND METHODS: Patients who underwent artificial urinary sphincter implant for non-neurogenic stress urinary incontinence between June 1989 and January 2020 were included in this single-centre retrospective series. All patients with a functional artificial urinary sphincter in situ were contacted to evaluate long-term functional outcomes using validated questionnaires.

RESULTS: A total of 263 patients were included in this retrospective series with a mean follow-up of 61 months. Explant-free survival after 5 years was 75% with a median time to explant of 16.2 years. Revision-free implant survival was 62% after 5 years with a median revision-free implant survival rate of 10.8 years. Previous pelvic irradiation, history of stricture disease and previous artificial urinary sphincter implant were associated with decreased implant survival. Overall social continence rate after 5 years was 60%. Prior radiation therapy, anticoagulation therapy and previous anti-incontinence surgery were associated with a higher incontinence risk. On long-term evaluation of 158 patients with their artificial urinary sphincter currently in situ, 51% were socially continent and 29% reported they were totally dry. Of these patients, 92% indicated to be satisfied with their current continence status.

CONCLUSION: A significant proportion of patients undergoing artificial urinary sphincter implant incontinence needed revision or explant surgery. Long-term continence rates are acceptable but tend to decrease by time. Nonetheless, if patients can maintain a functional AUS in situ, long-term patient satisfaction rates remain high.