MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2018.05.010

Медицинская библиотека · The Journal of arthroplasty · 2018

Level and Downhill Walking to Assess Implant Functionality in Bicruciate- and Posterior Cruciate-Retaining Total Knee Arthroplasty.

Simon Jacqueline C, Della Valle Craig J, Wimmer Markus A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The goal of this study is to set up a functional motion analysis test to examine effects of the anterior cruciate ligament in total knee arthroplasty (TKA) patients by comparing knee kinematics, kinetics, and muscle activation patterns during level and downhill walking for patients with posterior cruciate-retaining (PCR) and bicruciate-retaining (BiCR) TKAs.

METHODS

Motion and electromyography (EMG) data were collected for 12 subjects (4/8 male/female, 64 ± 11 years, 31.3 ± 7.3 body mass index, 6/6 right/left) with BiCR TKAs and 15 subjects (6/9 male/female, 67 ± 7 years, 30.5 ± 5.1 body mass index, 4/11 right/left) with PCR TKAs during level and downhill walking using the point cluster marker set and surface electrodes placed on the vastus medialis obliquus, rectus femoris, biceps femoris, and semitendinosus muscles.

RESULTS

Level walking exhibited no significant differences in knee kinematics, kinetics, or EMG patterns. During downhill walking, BiCR subjects had significantly lower peak muscle activity in the vastus medialis obliquus and rectus femoris (P = .045 and .018, respectively), a trending higher peak knee flexion moment (2.0 ± 0.6% BW*HT vs 1.5 ± 0.6% BW*HT, P = .076), and significantly more knee flexion at heel strike (5.1° ± 4.7° vs 1.8° ± 2.8°, P = .044) compared with PCR subjects.

CONCLUSION

Anterior cruciate ligament retention led to altered muscle recruitment during downhill walking in BiCR subjects compared with PCR subjects; thus, BiCR TKAs may offer some neuromuscular benefits for stabilizing the knee joint. In conclusion, level and downhill walking knee kinematics and kinetics combined with corresponding quadriceps and hamstrings EMG signals begin to build an overall picture of implant functionality.

Для цитирования: Simon Jacqueline C, Della Valle Craig J, Wimmer Markus A. Level and Downhill Walking to Assess Implant Functionality in Bicruciate- and Posterior Cruciate-Retaining Total Knee Arthroplasty.. The Journal of arthroplasty. 2018. DOI: 10.1016/j.arth.2018.05.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.