m+Medelevator.RU
← Поиск публикаций
Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition · 2016

[Determination of Nicotine and Cotinine in Urine by Dispersive Liquid-Liquid Microextraction Combined with Gas Chromatography-Mass Spectrometry].

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Yan, Li Yan, Zhu Jing, Lei Lei, Zheng Qian-yi, Zou Xiao-li

Аннотация

OBJECTIVE: To develop a method for the determination of nicotine and cotinine in urine samples by dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography-mass spectrometry (DLLME-GC/MS).

METHODS: The experimental conditions for GC-MS and DLLME were investigated in detail. DLLME was performed with the following procedure: 5 mL of urine sample was adjusted to pH9. 0 with NaOH solution; NaCl was added to increase ionic strength; 100 µL chloroform (containing internal standard of quinolone) as extractant was mixed with 1 000 pL methanol as dispersant and then injected into the urine sample to make it emulsified and dispersed. The sample solution was centrifuged for 5 min at 4,000 r/min, and 1 µL of its extraction solvent was injected into the GC/MS system for analysis. GC separation was performed with DB-5 column under programmed temperature. Nicotine and cotinine were quantified using selected ion monitoring (SIM) mode of mass spectrum detection and internal standard working curve.

RESULTS: Good linear relationship was obtained for detecting nicotine and cotinine ranging from 0. 2 ng/mL to 100 ng/mL, with a detection limit of 0. 010 ng/mL and 0. 022 ng/mL for nicotine and cotinine respectively. The relative standard derivation (RSD) for determination of nicotine and cotinine in urine samples were 8.2% and 9.6% respectively. The spiked recoveries ranged from 92.0% to 108.0% for nicotine, 83.0% to 110.0% for cotinine.

CONCLUSION: The method is rapid, sensitive, accurate and simple, with little consumption of organic solvent. It is suitable for determination of nicotine and cotinine in urine, and can meet the requirements for evaluating human tobacco exposure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты