DOI 10.1080/14767058.2020.1856068
C-reactive protein in early-onset neonatal sepsis - a cutoff point for CRP value as a predictor of early-onset neonatal sepsis in term and late preterm infants early after birth?
Аннотация
OBJECTIVE
To identify whether the first plasma C-reactive protein values taken 6-8 h postpartum are predictive of the clinical early-onset neonatal sepsis (cEONS).
STUDY
DESIGN
We retrospectively analyzed C-reactive protein (CRP) values of 400 neonates, including 28 with cEONS, who underwent plasma CRP measurements as part of sepsis work-up. To determine whether the first CRP measurement is predictive of cEONS, logistic regression was used with CRP as an independent variable and cEONS (yes/no) as a dependent variable.
RESULT: A moderate predictive ability of the first CRP measurement (odds ratio 1.4, CI: [1.13, 1.76], p=.003) was revealed, at a 5.3 mg/L threshold. However, it resulted in poor sensitivity of 50%, and a false positive rate of 30%. Increasing the sensitivity to 75% or 90% lead to increased false-positive rates of 55% and 75%, respectively.
CONCLUSIONS
Our findings suggest that the first CRP value taken in neonates is a weak predictor of cEONS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.