DOI 10.1007/s10877-021-00789-8

Медицинская библиотека · Journal of clinical monitoring and computing · 2021

Accuracy of pulse pressure variations for fluid responsiveness prediction in mechanically ventilated patients with biphasic positive airway pressure mode.

Bataille Benoît, Le Moal David, Renault Thomas, Cocquet Pierre, de Selle Jade, Silva Stein

СтатьяПеревод в очереди

Аннотация

The accuracy of pulse pressure variation (PPV) to predict fluid responsiveness using pressure-controlled (PC) instead of volume-controlled modes is under debate. To specifically address this issue, we designed a study to evaluate the accuracy of PPV to predict fluid responsiveness in severe septic patients who were mechanically ventilated with biphasic positive airway pressure (BIPAP) PC-ventilation mode. 45 patients with sepsis or septic shock and who were mechanically ventilated with BIPAP mode and a target tidal volume of 7-8 ml/kg were included. PPV was automatically assessed at baseline and after a standard fluid challenge (Ringer's lactate 500 ml). A 15% increase in stroke volume (SV) defined fluid responsiveness. The predictive value of PPV was evaluated through a receiver operating characteristic (ROC) curve analysis and "gray zone" statistical approach. 20 (44%) patients were considered fluid responders. We identified a significant relationship between PPV decrease after volume expansion and SV increase (spearman ρ = - 0.5, p < 0.001). The area under ROC curve for PPV was 0.71 (95%CI 0.56-0.87, p = 0.007). The best cut-off (based on Youden's index) was 8%, with a sensitivity of 80% and specificity of 60%. Using a gray zone approach, we identified that PPV values comprised between 5 and 15% do not allow a reliable fluid responsiveness prediction. In critically ill septic patients ventilated under BIPAP mode, PPV appears to be an accurate method for fluid responsiveness prediction. However, PPV values comprised between 5 and 15% constitute a gray zone that does not allow a reliable fluid responsiveness prediction.

Для цитирования: Bataille Benoît, Le Moal David, Renault Thomas, Cocquet Pierre, de Selle Jade, Silva Stein. Accuracy of pulse pressure variations for fluid responsiveness prediction in mechanically ventilated patients with biphasic positive airway pressure mode.. Journal of clinical monitoring and computing. 2021. DOI: 10.1007/s10877-021-00789-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.