MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-018-21600-w

Медицинская библиотека · Scientific reports · 2018

Angiotensin-converting enzyme inhibitor reduces scar formation by inhibiting both canonical and noncanonical TGF-β1 pathways.

Fang Qing-Qing, Wang Xiao-Feng, Zhao Wan-Yi, Ding Shi-Li, Shi Bang-Hui, Xia Ying, Yang Hu, Wu Li-Hong, Li Cai-Yun, Tan Wei-Qiang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Angiotensin-converting enzyme inhibitors (ACEIs) can improve the fibrotic processes in many internal organs. Recent studies have shown a relationship between ACEI with cutaneous scar formation, although it has not been confirmed, and the underlying mechanism is unclear. In this study, we cultured mouse NIH 3T3 fibroblasts with different concentrations of ACEI. We measured cell proliferation with a Cell Counting Kit-8 and collagen expression with a Sirius Red Collagen Detection Kit. Flow cytometry and western blotting were used to detect transforming growth factor β1 (TGF-β1) signaling. We also confirmed the potential antifibrotic activity of ACEI in a rat scar model. ACEI reduced fibroblast proliferation, suppressed collagen and TGF-β1 expression, and downregulated the phosphorylation of SMAD2/3 and TAK1, both in vitro and in vivo. A microscopic examination showed that rat scars treated with ramipril or losartan were not only narrower than in the controls, but also displayed enhanced re-epithelialization and neovascularization, and the formation of organized granulation tissue. These data indicate that ACEI inhibits scar formation by suppressing both TGF-β1/SMAD2/3 and TGF-β1/TAK1 pathways, and may have clinical utility in the future.

Для цитирования: Fang Qing-Qing, Wang Xiao-Feng, Zhao Wan-Yi, Ding Shi-Li, Shi Bang-Hui, Xia Ying, Yang Hu, Wu Li-Hong, Li Cai-Yun, Tan Wei-Qiang. Angiotensin-converting enzyme inhibitor reduces scar formation by inhibiting both canonical and noncanonical TGF-β1 pathways.. Scientific reports. 2018. DOI: 10.1038/s41598-018-21600-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.